## 2026-05-13 Release Notice DEWETRON TRION API R8.1.0
Revision: 528f98f6e62d43db3922896b81cf7ea97c8d3638
Components | Version
--------------------------------|--------------------------
DEWETRON Explorer | 8.1.0.9904
DEWETRON TRION API | 8.1.0.9904
DEWETRON TRION driver | 8.1.0.9904
DEWETRON DEWE2 driver | 8.1.0.9904
## Files
DEWETRON-TRION-Applications-8.1.0.9904.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R8.1.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-SUB8: Fixed a phase shift between TRION3-18XX-POWER and SUB8 when using SUB-XV modules.
* TRION3-24XX-ACC: Fixed a temperature dependent issue on CH6
* TRION3-24XX-ACC: Fixed an issue when sometimes the acquisition start was delayed.
* TRION3-CONTROLLER: Fixed an issue when as PTP Master the UTC Offset could not be set.
## New Firmwares
HW Support TRION3 modules | Firmware
--------------------------------|-----------
TRION3-1810-SUB-8 | FW: 0021
TRION3-1810M-SUB-8 | FW: 0021
TRION3-1820-SUB-8 | FW: 0021
TRION3-2402-ACC-6-BNC | FW: 0024
TRION3-2402-LV-6-BNC | FW: 0024
TRION3-2420-ACC-6-BNC | FW: 0024
TRION3-2420-LV-6-BNC | FW: 0024
HW Support Chassis modules | Firmware
--------------------------------|-----------
TRION3-CONTROLLER | FW: 0053 MCU: 01010161
HW Support LITE[PA] modules | Firmware
--------------------------------|-----------
LITEPA-CONTROLLER | FW: 0053
## 2026-05-13 Release Notice DEWETRON TRION API R8.1.0
Revision: 528f98f6e62d43db3922896b81cf7ea97c8d3638
Components | Version
--------------------------------|--------------------------
DEWETRON Explorer | 8.1.0.9904
DEWETRON TRION API | 8.1.0.9904
DEWETRON TRION driver | 8.1.0.9904
DEWETRON DEWE2 driver | 8.1.0.9904
## Files
DEWETRON-TRION-Applications-8.1.0.9904.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R8.1.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-SUB8: Fixed a phase shift between TRION3-18XX-POWER and SUB8 when using SUB-XV modules.
* TRION3-24XX-ACC: Fixed a temperature dependent issue on CH6
* TRION3-24XX-ACC: Fixed an issue when sometimes the acquisition start was delayed.
* TRION3-CONTROLLER: Fixed an issue when as PTP Master the UTC Offset could not be set.
## New Firmwares
HW Support TRION3 modules | Firmware
--------------------------------|-----------
TRION3-1810-SUB-8 | FW: 0021
TRION3-1810M-SUB-8 | FW: 0021
TRION3-1820-SUB-8 | FW: 0021
TRION3-2402-ACC-6-BNC | FW: 0024
TRION3-2402-LV-6-BNC | FW: 0024
TRION3-2420-ACC-6-BNC | FW: 0024
TRION3-2420-LV-6-BNC | FW: 0024
HW Support Chassis modules | Firmware
--------------------------------|-----------
TRION3-CONTROLLER | FW: 0053 MCU: 01010161
HW Support LITE[PA] modules | Firmware
--------------------------------|-----------
LITEPA-CONTROLLER | FW: 0053
## 2025-09-24 Release Notice DEWETRON TRION API R7.6.2
Revision: 5c00985d91c62fede8d5bb75ecb27b58430c3710
Components | Version
--------------------------------|--------------------------
DEWETRON Explorer | 7.6.2.7554
DEWETRON TRION API | 7.6.2.7554
DEWETRON TRION driver | 7.6.2.7554
DEWETRON DEWE2 driver | 7.6.2.7554
## Files
DEWETRON-TRION-Applications-7.6.2.7554.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.6.2 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-1820-ACC-8-MD new firmware (FW 0055)
* Fix for ID011 - TRION3-1820-ACC-8-MD: Sometimes acquisition won't start
* Support for manual clock selection on TRION3-CONTROLLER (FW 0022)
* Fix for ID012 - TRION-SUB-XV sometimes measure wrong data or show no samples at all
## New Firmwares
HW Support TRION3 modules | Firmware
--------------------------------|-----------
TRION3-1820-ACC-8-MD | FW: 0055
HW Support Chassis modules | Firmware
--------------------------------|-----------
TRION3-CONTROLLER | FW: 0022
TRION3-CONTROLLER | FW: 0050 MCU: 01000137
HW Support LITE[PA] modules | Firmware
--------------------------------|-----------
LITEPA-CONTROLLER | FW: 0050
## Known Issues
* TRION3-CONTROLLER: Frequency Out doesn't work
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.7.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* Dewetron Explorer - Remote Network Settings window does not load actual settings
* TRION3-CONTROLLER: Fix for IRIG sync frequency jump
* TRION3-CONTROLLER: Fix for Frequency Out doesn't work
* TRION3-CONTROLLER: Fix for PTP-Master cold start - invalid sync signal
* TRION3-POWER: Wrong measurement on SUB-XV @3MS
* TRION3-POWER: Fix for spikes on Channels
* TRION-1620-LV/ACC: Fix for DCDC Control fails
* TRION3-POWER & TRION-SUB-CT: Fix for Offset Jumps between several restarts.
* TRION-SUB-XV: Fix for wrong measurement scaling
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.7.1 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* Fixed the TRION-SUB-XV DC-Accuracy Problem with firmware 0084 [ID015]
## 2026-02-19 Release Notice DEWETRON TRION API R8.0.0
Revision: 5b377c100c887e7f4e18b1736b9f4c679e8f1d57
Components | Version
--------------------------------|--------------------------
DEWETRON Explorer | 8.0.0.9068
DEWETRON TRION API | 8.0.0.9068
DEWETRON TRION driver | 8.0.0.9068
DEWETRON DEWE2 driver | 8.0.0.9068
## Files
DEWETRON-TRION-Applications-8.0.0.9068.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R8.0.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-CONTROLLER: Added support for gPTP (IEEE 802.1AS)
* TRION3-24XX-ACC, TRION3-24XX-LV support added
* NEXDAQ: Fixed an issue, where CAN-FD-Frames would only correctly transmit the first 8 bytes of a message
* NEXDAQ-1000: CNT1 to CNT4 can now be used with 1MS, avoiding artifacts in frequency-measurement due to sample-reduction
## 2025-09-24 Release Notice DEWETRON TRION API R7.6.2
Revision: 5c00985d91c62fede8d5bb75ecb27b58430c3710
Components | Version
--------------------------------|--------------------------
DEWETRON Explorer | 7.6.2.7554
DEWETRON TRION API | 7.6.2.7554
DEWETRON TRION driver | 7.6.2.7554
DEWETRON DEWE2 driver | 7.6.2.7554
## Files
DEWETRON-TRION-Applications-7.6.2.7554.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.6.2 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-1820-ACC-8-MD new firmware (FW 0055)
* Fix for ID011 - TRION3-1820-ACC-8-MD: Sometimes acquisition won't start
* Support for manual clock selection on TRION3-CONTROLLER (FW 0022)
* Fix for ID012 - TRION-SUB-XV sometimes measure wrong data or show no samples at all
## New Firmwares
HW Support TRION3 modules | Firmware
--------------------------------|-----------
TRION3-1820-ACC-8-MD | FW: 0055
HW Support Chassis modules | Firmware
--------------------------------|-----------
TRION3-CONTROLLER | FW: 0022
TRION3-CONTROLLER | FW: 0050 MCU: 01000137
HW Support LITE[PA] modules | Firmware
--------------------------------|-----------
LITEPA-CONTROLLER | FW: 0050
## Known Issues
* TRION3-CONTROLLER: Frequency Out doesn't work
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.7.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* Dewetron Explorer - Remote Network Settings window does not load actual settings
* TRION3-CONTROLLER: Fix for IRIG sync frequency jump
* TRION3-CONTROLLER: Fix for Frequency Out doesn't work
* TRION3-CONTROLLER: Fix for PTP-Master cold start - invalid sync signal
* TRION3-POWER: Wrong measurement on SUB-XV @3MS
* TRION3-POWER: Fix for spikes on Channels
* TRION-1620-LV/ACC: Fix for DCDC Control fails
* TRION3-POWER & TRION-SUB-CT: Fix for Offset Jumps between several restarts.
* TRION-SUB-XV: Fix for wrong measurement scaling
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.7.1 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* Fixed the TRION-SUB-XV DC-Accuracy Problem with firmware 0084 [ID015]
## 2026-02-19 Release Notice DEWETRON TRION API R8.0.0
Revision: 5b377c100c887e7f4e18b1736b9f4c679e8f1d57
Components | Version
--------------------------------|--------------------------
DEWETRON Explorer | 8.0.0.9068
DEWETRON TRION API | 8.0.0.9068
DEWETRON TRION driver | 8.0.0.9068
DEWETRON DEWE2 driver | 8.0.0.9068
## Files
DEWETRON-TRION-Applications-8.0.0.9068.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R8.0.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-CONTROLLER: Added support for gPTP (IEEE 802.1AS)
* TRION3-24XX-ACC, TRION3-24XX-LV support added
* NEXDAQ: Fixed an issue, where CAN-FD-Frames would only correctly transmit the first 8 bytes of a message
* NEXDAQ-1000: CNT1 to CNT4 can now be used with 1MS, avoiding artifacts in frequency-measurement due to sample-reduction
SELECT COUNT(*) AS `count` FROM `dewe_cakeisalie`.`products` AS `Product` WHERE `Product`.`id` = 'dewe3-a12-a8'
1
1
0
SELECT `Product`.`name`, `Product`.`sort`, `Product`.`description`, `Product`.`id`, `Product`.`slug`, `Product`.`active`, `Product`.`permissions`, `Productgroup`.`slug`, `Productgroup`.`name`, `Productgroup`.`id` FROM `dewe_cakeisalie`.`products` AS `Product` LEFT JOIN `dewe_cakeisalie`.`productgroups` AS `Productgroup` ON (`Product`.`productgroup_id` = `Productgroup`.`id` AND `Productgroup`.`active` = '1' AND (`Productgroup`.`permissions` & 1 != 0)) WHERE `Product`.`active` = '1' AND (`Product`.`permissions` & 1 != 0) AND `Product`.`slug` = 'dewe3-a12-a8' ORDER BY `Productgroup`.`sort` ASC, `Productgroup`.`name` ASC LIMIT 1
1
1
0
SELECT `Download`.`description`, `Download`.`language`, `Download`.`filename`, `Download`.`releasedate`, `Download`.`name`, `Download`.`id`, `Download`.`active`, `Download`.`filesize`, `Download`.`version`, `Download`.`oscompat`, `Download`.`downloadtype`, `Download`.`advancedOnly`, `Download`.`internalOnly`, `Download`.`md5`, `Download`.`sha1`, `Download`.`download_count`, `DownloadsProduct`.`product_id`, `DownloadsProduct`.`download_id`, `DownloadsProduct`.`id` FROM `dewe_cakeisalie`.`downloads` AS `Download` JOIN `dewe_cakeisalie`.`downloads_products` AS `DownloadsProduct` ON (`DownloadsProduct`.`product_id` = '68c15db5-97f0-4cea-884b-4791d9c49a3c' AND `DownloadsProduct`.`download_id` = `Download`.`id`) WHERE `Download`.`active` = '1' AND (`Download`.`permissions` & 1 != 0) ORDER BY `Download`.`downloadtype` ASC, `Download`.`sort` ASC, `Download`.`name` ASC
15
15
1
maybe slow
Query Explain:
Click an "Explain" link above, to see the query explanation.
description<p><code>## 2025-09-24 Release Notice DEWETRON TRION API R7.6.2<br />
Revision: 5c00985d91c62fede8d5bb75ecb27b58430c3710<br />
Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 7.6.2.7554<br />
DEWETRON TRION API | 7.6.2.7554<br />
DEWETRON TRION driver | 7.6.2.7554<br />
DEWETRON DEWE2 driver | 7.6.2.7554<br />
## Files<br />
DEWETRON-TRION-Applications-7.6.2.7554.exe<br />
## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R7.6.2 or higher<br />
* Windows 10 64-Bit or better<br />
## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade<br />
## Fixes and Changes<br />
* TRION3-1820-ACC-8-MD new firmware (FW 0055)<br />
* Fix for ID011 - TRION3-1820-ACC-8-MD: Sometimes acquisition won't start<br />
* Support for manual clock selection on TRION3-CONTROLLER (FW 0022)<br />
* Fix for ID012 - TRION-SUB-XV sometimes measure wrong data or show no samples at all<br />
## New Firmwares<br />
HW Support TRION3 modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-1820-ACC-8-MD | FW: 0055<br />
HW Support Chassis modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-CONTROLLER | FW: 0022<br />
TRION3-CONTROLLER | FW: 0050 MCU: 01000137<br />
HW Support LITE[PA] modules | Firmware<br />
--------------------------------|-----------<br />
LITEPA-CONTROLLER | FW: 0050<br />
<br />
## Known Issues<br />
* TRION3-CONTROLLER: Frequency Out doesn't work</code><br />
</p>
language
filenameDEWETRON TRION R7.6.2.zip
releasedate2025-09-24
nameDEWETRON TRION R7.6.2.zip
id68e4d1e2-e1a8-42c7-a89b-4ecfd9c49a3c
active(true)
filesize305968221
versionR7.6.2
oscompatWindows
downloadtypeInstaller (archive)
advancedOnly(false)
internalOnly(false)
md5e5789d210083829be6f8740dc35661df
sha1d451f610291a456f6cf8daa37a056d12af668b96
download_count188
DownloadsProduct(array)
product_id68c15db5-97f0-4cea-884b-4791d9c49a3c
download_id68e4d1e2-e1a8-42c7-a89b-4ecfd9c49a3c
id6920429f-4a94-45dc-bc8e-46edd9c49a3c
7(array)
description<p><code>## 2025-11-07 Release Notice DEWETRON TRION API R7.7.0</code></p>
<p><code>Revision: e2be43084954fb49f92e44007ee6e4ec56616c19 </code></p>
<p><code>Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 7.7.0.8215<br />
DEWETRON TRION API | 7.7.0.8215<br />
DEWETRON TRION driver | 7.7.0.8215<br />
DEWETRON DEWE2 driver | 7.7.0.8215</code></p>
<p><code>## Files<br />
DEWETRON-TRION-Applications-7.7.0.8215.exe</code></p>
<p><code>## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R7.7.0 or higher<br />
* Windows 10 64-Bit or better</code></p>
<p><code>## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade</code></p>
<p><code>## Fixes and Changes<br />
* Dewetron Explorer - Remote Network Settings window does not load actual settings<br />
* TRION3-CONTROLLER: Fix for IRIG sync frequency jump<br />
* TRION3-CONTROLLER: Fix for Frequency Out doesn't work<br />
* TRION3-CONTROLLER: Fix for PTP-Master cold start - invalid sync signal<br />
* TRION3-POWER: Wrong measurement on SUB-XV @3MS<br />
* TRION3-POWER: Fix for spikes on Channels<br />
* TRION-1620-LV/ACC: Fix for DCDC Control fails<br />
* TRION3-POWER & TRION-SUB-CT: Fix for Offset Jumps between several restarts.<br />
* TRION-SUB-XV: Fix for wrong measurement scaling</code></p>
language
filenameDEWETRON TRION R7.7.0.zip
releasedate2025-11-21
nameDEWETRON TRION R7.7.0.zip
id692041c8-3b94-4eeb-ac66-4dafd9c49a3c
active(true)
filesize318050116
versionR7.7.0
oscompatWindows
downloadtypeInstaller (archive)
advancedOnly(false)
internalOnly(false)
md5d9825420d0c18f4738b297861c97307d
sha1b9ea39d06990817a4fee288303e4bd136d34f0de
download_count6
DownloadsProduct(array)
product_id68c15db5-97f0-4cea-884b-4791d9c49a3c
download_id692041c8-3b94-4eeb-ac66-4dafd9c49a3c
id692880d0-dcb4-4f74-85f4-4ee1d9c49a3c
8(array)
description<p><tt>## 2025-11-27 Release Notice DEWETRON TRION API R7.7.1</tt></p>
<p><tt>Revision: 3291af01d8efa69078acc73564d0367fa20e278f </tt></p>
<p><tt>Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 7.7.1.8228<br />
DEWETRON TRION API | 7.7.1.8228<br />
DEWETRON TRION driver | 7.7.1.8228<br />
DEWETRON DEWE2 driver | 7.7.1.8228</tt></p>
<p><tt>## Files<br />
DEWETRON-TRION-Applications-7.7.1.8228.exe</tt></p>
<p><tt>## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R7.7.1 or higher<br />
* Windows 10 64-Bit or better</tt></p>
<p><tt>## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade</tt></p>
<p><tt>## Fixes and Changes<br />
* Fixed the TRION-SUB-XV DC-Accuracy Problem with firmware 0084 [ID015]</tt></p>
<p><tt>## New Firmwares</tt></p>
<p><tt>HW Support TRION3 modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-1810-HV-8 | FW: 0085<br />
TRION3-1810-POWER-4-V2 | FW: 0085<br />
TRION3-1810M-POWER-4 | FW: 0085<br />
TRION3-1810M-POWER-4-V2 | FW: 0085<br />
TRION3-1820-POWER-4 | FW: 0085<br />
TRION3-1820-POWER-4-V2 | FW: 0085</tt></p>
<p><tt>HW Support TRION modules | Firmware<br />
--------------------------------|-----------<br />
TRION-1810-HV-4 | FW: 0085<br />
TRION-1810-HV-8 | FW: 0085<br />
TRION-1810M-POWER-4 | FW: 0085<br />
TRION-1820-POWER-4 | FW: 0085</tt></p>
<p><tt>HW Support LITE[PA] modules | Firmware<br />
--------------------------------|-----------<br />
LITEPA-4 | FW: 0085</tt></p>
language
filenameDEWETRON TRION R7.7.1.zip
releasedate2025-11-28
nameDEWETRON TRION R7.7.1.zip
id69288003-ab74-4f40-a34b-4381d9c49a3c
active(true)
filesize324548323
versionR7.7.1
oscompatWindows
downloadtypeInstaller (archive)
advancedOnly(false)
internalOnly(false)
md552a97c5571c08596d0aae8b7d48265e8
sha1247fc80a0aa4fd083eb98e9947562d93a541d50a
download_count164
DownloadsProduct(array)
product_id68c15db5-97f0-4cea-884b-4791d9c49a3c
download_id69288003-ab74-4f40-a34b-4381d9c49a3c
id69a162ba-4d58-44f6-b35a-4dccd9c49a3c
9(array)
description<p><code>## 2026-02-19 Release Notice DEWETRON TRION API R8.0.0<br />
Revision: 5b377c100c887e7f4e18b1736b9f4c679e8f1d57<br />
Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 8.0.0.9068<br />
DEWETRON TRION API | 8.0.0.9068<br />
DEWETRON TRION driver | 8.0.0.9068<br />
DEWETRON DEWE2 driver | 8.0.0.9068<br />
## Files<br />
DEWETRON-TRION-Applications-8.0.0.9068.exe<br />
## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R8.0.0 or higher<br />
* Windows 10 64-Bit or better<br />
## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade<br />
## Fixes and Changes<br />
* TRION3-CONTROLLER: Added support for gPTP (IEEE 802.1AS)<br />
* TRION3-24XX-ACC, TRION3-24XX-LV support added<br />
* NEXDAQ: Fixed an issue, where CAN-FD-Frames would only correctly transmit the first 8 bytes of a message<br />
* NEXDAQ-1000: CNT1 to CNT4 can now be used with 1MS, avoiding artifacts in frequency-measurement due to sample-reduction<br />
<br />
## New Firmwares<br />
HW Support TRION3 modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-2402-ACC-6-BNC | FW: 0021<br />
TRION3-2420-ACC-6-BNC | FW: 0021<br />
TRION3-2402-LV-6-BNC | FW: 0021<br />
TRION3-2420-LV-6-BNC | FW: 0021<br />
TRION3-CONTROLLER | FW: 0052 MCU: 01000161<br />
<br />
HW Support Chassis modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-CONTROLLER | FW: 0052 MCU: 01000161</code></p>
language
filenameDEWETRON TRION R8.0.0.zip
releasedate2026-02-27
nameDEWETRON TRION R8.0.0.zip
id69a15ea1-dad0-427e-bf90-440bd9c49a3c
active(true)
filesize291146727
versionR8.0.0
oscompatWindows
downloadtypeInstaller (archive)
advancedOnly(false)
internalOnly(false)
md5dc0a338b96ca3d46e70c3257daa6039e
sha1bbceba89e586f73405478133a4a1e5a7d4e19644
download_count560
DownloadsProduct(array)
product_id68c15db5-97f0-4cea-884b-4791d9c49a3c
download_id69a15ea1-dad0-427e-bf90-440bd9c49a3c
id6a0d8f5d-7ad0-4d1b-8759-4d19d9c49a3c
10(array)
description<p><code>## 2025-09-24 Release Notice DEWETRON TRION API R7.6.2<br />
Revision: 5c00985d91c62fede8d5bb75ecb27b58430c3710<br />
Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 7.6.2.7554<br />
DEWETRON TRION API | 7.6.2.7554<br />
DEWETRON TRION driver | 7.6.2.7554<br />
DEWETRON DEWE2 driver | 7.6.2.7554<br />
## Files<br />
DEWETRON-TRION-Applications-7.6.2.7554.exe<br />
## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R7.6.2 or higher<br />
* Windows 10 64-Bit or better<br />
## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade<br />
## Fixes and Changes<br />
* TRION3-1820-ACC-8-MD new firmware (FW 0055)<br />
* Fix for ID011 - TRION3-1820-ACC-8-MD: Sometimes acquisition won't start<br />
* Support for manual clock selection on TRION3-CONTROLLER (FW 0022)<br />
* Fix for ID012 - TRION-SUB-XV sometimes measure wrong data or show no samples at all<br />
## New Firmwares<br />
HW Support TRION3 modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-1820-ACC-8-MD | FW: 0055<br />
HW Support Chassis modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-CONTROLLER | FW: 0022<br />
TRION3-CONTROLLER | FW: 0050 MCU: 01000137<br />
HW Support LITE[PA] modules | Firmware<br />
--------------------------------|-----------<br />
LITEPA-CONTROLLER | FW: 0050<br />
## Known Issues<br />
* TRION3-CONTROLLER: Frequency Out doesn't work</code><br />
</p>
description<p><code>## 2025-11-07 Release Notice DEWETRON TRION API R7.7.0</code></p>
<p><code>Revision: e2be43084954fb49f92e44007ee6e4ec56616c19 </code></p>
<p><code>Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 7.7.0.8215<br />
DEWETRON TRION API | 7.7.0.8215<br />
DEWETRON TRION driver | 7.7.0.8215<br />
DEWETRON DEWE2 driver | 7.7.0.8215</code></p>
<p><code>## Files<br />
DEWETRON-TRION-Applications-7.7.0.8215.exe</code></p>
<p><code>## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R7.7.0 or higher<br />
* Windows 10 64-Bit or better</code></p>
<p><code>## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade</code></p>
<p><code>## Fixes and Changes<br />
* Dewetron Explorer - Remote Network Settings window does not load actual settings<br />
* TRION3-CONTROLLER: Fix for IRIG sync frequency jump<br />
* TRION3-CONTROLLER: Fix for Frequency Out doesn't work<br />
* TRION3-CONTROLLER: Fix for PTP-Master cold start - invalid sync signal<br />
* TRION3-POWER: Wrong measurement on SUB-XV @3MS<br />
* TRION3-POWER: Fix for spikes on Channels<br />
* TRION-1620-LV/ACC: Fix for DCDC Control fails<br />
* TRION3-POWER & TRION-SUB-CT: Fix for Offset Jumps between several restarts.<br />
* TRION-SUB-XV: Fix for wrong measurement scaling</code></p>
description<p><br />
<code>## 2026-02-19 Release Notice DEWETRON TRION API R8.0.0<br />
Revision: 5b377c100c887e7f4e18b1736b9f4c679e8f1d57<br />
Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 8.0.0.9068<br />
DEWETRON TRION API | 8.0.0.9068<br />
DEWETRON TRION driver | 8.0.0.9068<br />
DEWETRON DEWE2 driver | 8.0.0.9068<br />
## Files<br />
DEWETRON-TRION-Applications-8.0.0.9068.exe<br />
## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R8.0.0 or higher<br />
* Windows 10 64-Bit or better<br />
## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade<br />
## Fixes and Changes<br />
* TRION3-CONTROLLER: Added support for gPTP (IEEE 802.1AS)<br />
* TRION3-24XX-ACC, TRION3-24XX-LV support added<br />
* NEXDAQ: Fixed an issue, where CAN-FD-Frames would only correctly transmit the first 8 bytes of a message<br />
* NEXDAQ-1000: CNT1 to CNT4 can now be used with 1MS, avoiding artifacts in frequency-measurement due to sample-reduction<br />
<br />
## New Firmwares<br />
HW Support TRION3 modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-2402-ACC-6-BNC | FW: 0021<br />
TRION3-2420-ACC-6-BNC | FW: 0021<br />
TRION3-2402-LV-6-BNC | FW: 0021<br />
TRION3-2420-LV-6-BNC | FW: 0021<br />
TRION3-CONTROLLER | FW: 0052 MCU: 01000161<br />
<br />
HW Support Chassis modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-CONTROLLER | FW: 0052 MCU: 01000161</code><br />
</p>