Skip to content
DEWETRON Customer Care Center

DEWE3-A12/A8

 
belongs to: DEWE3: A-series
DEWE3-A8-PA 3D-drawing PDF
PDF584 KB
DEWE3-A8-PA_Main_Dimensions.pdf
md5: 3d7bb3131db42f335a965bccb7a0b06a
2026-06
2026-06
DEWE3-A8-PA 3D-Drawing STP
STP53.57 MB
DEWE3-A8-PA_Export3D.stp
md5: 6886eecf181132bb56bd33d03650ae8e
2026-06
2026-06
DEWE3-A8_DEWE3-A12_3D-drawing PDF
PDF37 KB
DEWE3-A8_DEWE3-A12_main dimensions.pdf
md5: 8a7d52e9d2e35ee302d06095ec6ade2f
1.0.0
Language: English
DEWE3-A8_DEWE3-A12__3D-drawing STP
STP67.60 MB
DEWE3-A8_DEWE3-A12__Export3D.stp
md5: 98376d3ceeb520e28086c803f8033da9
1.0.0
Language: English
DEWE3-A8/A12/A8-PA Datasheet 1.0.2
PDF1.08 MB
DEWE3-A8_A12_A8-PA_datasheet_102ex.pdf
md5: 9aa9b0cebb93cd9da9eddf5c7286ebce
1.0.2
Language: English
DoD ready instruments datasheet
PDF250 KB
DoD-ready-instruments_datasheet_101ex.pdf
md5: 35aaef4406b97e43964205821d007257
1.0.1
Language: English
DEWETRON TRION R8.2.0.zip
ZIP296.00 MBNew
DEWETRON TRION R8.2.0.zip
md5: 7ec6238fbcdd4a9baad3ccf6fe89968d
R8.2.0
OS Compatibility: Windows
Notes for DEWETRON TRION R8.2.0.zip

## 2026-07-31 Release Notice DEWETRON TRION API R8.2.0

Revision: 7337aeee5b6d30313a108c1e8af8752ac003b684

 

Components                      | Version

--------------------------------|--------------------------

DEWETRON Explorer               | 8.2.0.10435

DEWETRON TRION API              | 8.2.0.10435

DEWETRON TRION driver           | 8.2.0.10435

DEWETRON DEWE2 driver           | 8.2.0.10435

 

## Files

DEWETRON-TRION-Applications-8.2.0.10435.exe

 

## Requirements

* Update all TRION modules to the latest firmware included in this release

* Use OXYGEN R8.1.0 or higher

* Windows 10 64-Bit or better

 

## Installation procedure

* Install TRION applications

* Reboot system (if requested by the installer)

* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)

* Power-cycle TRION boards (Power down system, then restart)

* Start DEWETRON Explorer and check for a successful firmware upgrade

 

## Fixes and Changes

* TRION-2402-dACC: Fix counter treshold and retrigger inconsistencies.

* TRION3-CANFD: Fixed an issue when CAN messages are delayed.

* TRION3-24XX-ACC: Fixed FIR-filter data latch bug and ADC read data timings.

 

## New Firmwares

HW Support TRION3 modules       | Firmware

--------------------------------|-----------

TRION3-2402-ACC-6-BNC           | FW: 0027

TRION3-2402-LV-6-BNC            | FW: 0027

TRION3-2420-ACC-6-BNC           | FW: 0027

TRION3-2420-LV-6-BNC            | FW: 0027

DEWETRON-TRION-Applications-8.2.0.10435.exe
EXE296.38 MBNew
DEWETRON-TRION-Applications-8.2.0.10435.exe
md5: 92b8dab47da5e57c8564fa44618a970d
R8.2.0
OS Compatibility: Windows
Notes for DEWETRON-TRION-Applications-8.2.0.10435.exe

## 2026-07-31 Release Notice DEWETRON TRION API R8.2.0

Revision: 7337aeee5b6d30313a108c1e8af8752ac003b684

 

Components                      | Version

--------------------------------|--------------------------

DEWETRON Explorer               | 8.2.0.10435

DEWETRON TRION API              | 8.2.0.10435

DEWETRON TRION driver           | 8.2.0.10435

DEWETRON DEWE2 driver           | 8.2.0.10435

 

## Files

DEWETRON-TRION-Applications-8.2.0.10435.exe

 

## Requirements

* Update all TRION modules to the latest firmware included in this release

* Use OXYGEN R8.1.0 or higher

* Windows 10 64-Bit or better

 

## Installation procedure

* Install TRION applications

* Reboot system (if requested by the installer)

* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)

* Power-cycle TRION boards (Power down system, then restart)

* Start DEWETRON Explorer and check for a successful firmware upgrade

 

## Fixes and Changes

* TRION-2402-dACC: Fix counter treshold and retrigger inconsistencies.

* TRION3-CANFD: Fixed an issue when CAN messages are delayed.

* TRION3-24XX-ACC: Fixed FIR-filter data latch bug and ADC read data timings.

 

## New Firmwares

HW Support TRION3 modules       | Firmware

--------------------------------|-----------

TRION3-2402-ACC-6-BNC           | FW: 0027

TRION3-2402-LV-6-BNC            | FW: 0027

TRION3-2420-ACC-6-BNC           | FW: 0027

TRION3-2420-LV-6-BNC            | FW: 0027

 

DEWETRON TRION R8.1.0.zip
ZIP310.90 MB
DEWETRON TRION R8.1.0.zip
md5: 1e86111b869c706c450b14267afa123e
R8.1.0
OS Compatibility: Windows
Notes for DEWETRON TRION R8.1.0.zip


## 2026-05-13 Release Notice DEWETRON TRION API R8.1.0
Revision: 528f98f6e62d43db3922896b81cf7ea97c8d3638
Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 8.1.0.9904
DEWETRON TRION API              | 8.1.0.9904
DEWETRON TRION driver           | 8.1.0.9904
DEWETRON DEWE2 driver           | 8.1.0.9904
## Files
DEWETRON-TRION-Applications-8.1.0.9904.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R8.1.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-SUB8: Fixed a phase shift between TRION3-18XX-POWER and SUB8 when using SUB-XV modules.
* TRION3-24XX-ACC: Fixed a temperature dependent issue on CH6
* TRION3-24XX-ACC: Fixed an issue when sometimes the acquisition start was delayed.
* TRION3-CONTROLLER: Fixed an issue when as PTP Master the UTC Offset could not be set.
## New Firmwares
HW Support TRION3 modules       | Firmware
--------------------------------|-----------
TRION3-1810-SUB-8               | FW: 0021
TRION3-1810M-SUB-8              | FW: 0021
TRION3-1820-SUB-8               | FW: 0021
TRION3-2402-ACC-6-BNC           | FW: 0024
TRION3-2402-LV-6-BNC            | FW: 0024
TRION3-2420-ACC-6-BNC           | FW: 0024
TRION3-2420-LV-6-BNC            | FW: 0024
HW Support Chassis modules      | Firmware
--------------------------------|-----------
TRION3-CONTROLLER               | FW: 0053   MCU: 01010161
HW Support LITE[PA] modules     | Firmware
--------------------------------|-----------
LITEPA-CONTROLLER               | FW: 0053

 

DEWETRON TRION R7.6.2.zip
ZIP291.79 MB
DEWETRON TRION R7.6.2.zip
md5: e5789d210083829be6f8740dc35661df
R7.6.2
OS Compatibility: Windows
Notes for DEWETRON TRION R7.6.2.zip

## 2025-09-24 Release Notice DEWETRON TRION API R7.6.2
Revision: 5c00985d91c62fede8d5bb75ecb27b58430c3710
Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 7.6.2.7554
DEWETRON TRION API              | 7.6.2.7554
DEWETRON TRION driver           | 7.6.2.7554
DEWETRON DEWE2 driver           | 7.6.2.7554
## Files
DEWETRON-TRION-Applications-7.6.2.7554.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.6.2 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-1820-ACC-8-MD new firmware (FW 0055)
  * Fix for ID011 - TRION3-1820-ACC-8-MD: Sometimes acquisition won't start
* Support for manual clock selection on TRION3-CONTROLLER (FW 0022)
  * Fix for ID012 - TRION-SUB-XV sometimes measure wrong data or show no samples at all
## New Firmwares
HW Support TRION3 modules       | Firmware
--------------------------------|-----------
TRION3-1820-ACC-8-MD            | FW: 0055
HW Support Chassis modules      | Firmware
--------------------------------|-----------
TRION3-CONTROLLER               | FW: 0022
TRION3-CONTROLLER               | FW: 0050   MCU: 01000137
HW Support LITE[PA] modules     | Firmware
--------------------------------|-----------
LITEPA-CONTROLLER               | FW: 0050

## Known Issues
* TRION3-CONTROLLER: Frequency Out doesn't work

 

DEWETRON TRION R7.7.0.zip
ZIP303.32 MB
DEWETRON TRION R7.7.0.zip
md5: d9825420d0c18f4738b297861c97307d
R7.7.0
OS Compatibility: Windows
Notes for DEWETRON TRION R7.7.0.zip

## 2025-11-07 Release Notice DEWETRON TRION API R7.7.0

Revision: e2be43084954fb49f92e44007ee6e4ec56616c19 

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 7.7.0.8215
DEWETRON TRION API              | 7.7.0.8215
DEWETRON TRION driver           | 7.7.0.8215
DEWETRON DEWE2 driver           | 7.7.0.8215

## Files
DEWETRON-TRION-Applications-7.7.0.8215.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.7.0 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## Fixes and Changes
* Dewetron Explorer - Remote Network Settings window does not load actual settings
* TRION3-CONTROLLER: Fix for IRIG sync frequency jump
* TRION3-CONTROLLER: Fix for Frequency Out doesn't work
* TRION3-CONTROLLER: Fix for PTP-Master cold start - invalid sync signal
* TRION3-POWER: Wrong measurement on SUB-XV @3MS
* TRION3-POWER: Fix for spikes on Channels
* TRION-1620-LV/ACC: Fix for DCDC Control fails
* TRION3-POWER & TRION-SUB-CT: Fix for Offset Jumps between several restarts.
* TRION-SUB-XV: Fix for wrong measurement scaling

DEWETRON TRION R7.7.1.zip
ZIP309.51 MB
DEWETRON TRION R7.7.1.zip
md5: 52a97c5571c08596d0aae8b7d48265e8
R7.7.1
OS Compatibility: Windows
Notes for DEWETRON TRION R7.7.1.zip

## 2025-11-27 Release Notice DEWETRON TRION API R7.7.1

Revision: 3291af01d8efa69078acc73564d0367fa20e278f 

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 7.7.1.8228
DEWETRON TRION API              | 7.7.1.8228
DEWETRON TRION driver           | 7.7.1.8228
DEWETRON DEWE2 driver           | 7.7.1.8228

## Files
DEWETRON-TRION-Applications-7.7.1.8228.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.7.1 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## Fixes and Changes
* Fixed the TRION-SUB-XV DC-Accuracy Problem with firmware 0084 [ID015]

## New Firmwares

HW Support TRION3 modules       | Firmware
--------------------------------|-----------
TRION3-1810-HV-8                | FW: 0085
TRION3-1810-POWER-4-V2          | FW: 0085
TRION3-1810M-POWER-4            | FW: 0085
TRION3-1810M-POWER-4-V2         | FW: 0085
TRION3-1820-POWER-4             | FW: 0085
TRION3-1820-POWER-4-V2          | FW: 0085

HW Support TRION modules        | Firmware
--------------------------------|-----------
TRION-1810-HV-4                 | FW: 0085
TRION-1810-HV-8                 | FW: 0085
TRION-1810M-POWER-4             | FW: 0085
TRION-1820-POWER-4              | FW: 0085

HW Support LITE[PA] modules     | Firmware
--------------------------------|-----------
LITEPA-4                        | FW: 0085

DEWETRON TRION R8.0.0.zip
ZIP277.66 MB
DEWETRON TRION R8.0.0.zip
md5: dc0a338b96ca3d46e70c3257daa6039e
R8.0.0
OS Compatibility: Windows
Notes for DEWETRON TRION R8.0.0.zip

## 2026-02-19 Release Notice DEWETRON TRION API R8.0.0
Revision: 5b377c100c887e7f4e18b1736b9f4c679e8f1d57
Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 8.0.0.9068
DEWETRON TRION API              | 8.0.0.9068
DEWETRON TRION driver           | 8.0.0.9068
DEWETRON DEWE2 driver           | 8.0.0.9068
## Files
DEWETRON-TRION-Applications-8.0.0.9068.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R8.0.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-CONTROLLER: Added support for gPTP (IEEE 802.1AS)
* TRION3-24XX-ACC, TRION3-24XX-LV support added
* NEXDAQ: Fixed an issue, where CAN-FD-Frames would only correctly transmit the first 8 bytes of a message
* NEXDAQ-1000: CNT1 to CNT4 can now be used with 1MS, avoiding artifacts in frequency-measurement due to sample-reduction

## New Firmwares
HW Support TRION3 modules       | Firmware
--------------------------------|-----------
TRION3-2402-ACC-6-BNC           | FW: 0021
TRION3-2420-ACC-6-BNC           | FW: 0021
TRION3-2402-LV-6-BNC            | FW: 0021
TRION3-2420-LV-6-BNC            | FW: 0021
TRION3-CONTROLLER               | FW: 0052   MCU: 01000161

HW Support Chassis modules      | Firmware
--------------------------------|-----------
TRION3-CONTROLLER               | FW: 0052   MCU: 01000161

DEWETRON-TRION-Applications-7.6.2.7554.exe
EXE292.18 MB
DEWETRON-TRION-Applications-7.6.2.7554.exe
md5: 7a1437d242cd3a90469af5bf3f2ae643
R7.6.2
OS Compatibility: Windows
Notes for DEWETRON-TRION-Applications-7.6.2.7554.exe

## 2025-09-24 Release Notice DEWETRON TRION API R7.6.2
Revision: 5c00985d91c62fede8d5bb75ecb27b58430c3710
Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 7.6.2.7554
DEWETRON TRION API              | 7.6.2.7554
DEWETRON TRION driver           | 7.6.2.7554
DEWETRON DEWE2 driver           | 7.6.2.7554
## Files
DEWETRON-TRION-Applications-7.6.2.7554.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.6.2 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-1820-ACC-8-MD new firmware (FW 0055)
  * Fix for ID011 - TRION3-1820-ACC-8-MD: Sometimes acquisition won't start
* Support for manual clock selection on TRION3-CONTROLLER (FW 0022)
  * Fix for ID012 - TRION-SUB-XV sometimes measure wrong data or show no samples at all
## New Firmwares
HW Support TRION3 modules       | Firmware
--------------------------------|-----------
TRION3-1820-ACC-8-MD            | FW: 0055
HW Support Chassis modules      | Firmware
--------------------------------|-----------
TRION3-CONTROLLER               | FW: 0022
TRION3-CONTROLLER               | FW: 0050   MCU: 01000137
HW Support LITE[PA] modules     | Firmware
--------------------------------|-----------
LITEPA-CONTROLLER               | FW: 0050
## Known Issues
* TRION3-CONTROLLER: Frequency Out doesn't work

 

DEWETRON-TRION-Applications-7.7.0.8215.exe
EXE303.70 MB
DEWETRON-TRION-Applications-7.7.0.8215.exe
md5: 10f7d431796d9555cb00aa762a4f6f11
R7.7.0
OS Compatibility: Windows
Notes for DEWETRON-TRION-Applications-7.7.0.8215.exe

## 2025-11-07 Release Notice DEWETRON TRION API R7.7.0

Revision: e2be43084954fb49f92e44007ee6e4ec56616c19 

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 7.7.0.8215
DEWETRON TRION API              | 7.7.0.8215
DEWETRON TRION driver           | 7.7.0.8215
DEWETRON DEWE2 driver           | 7.7.0.8215

## Files
DEWETRON-TRION-Applications-7.7.0.8215.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.7.0 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## Fixes and Changes
* Dewetron Explorer - Remote Network Settings window does not load actual settings
* TRION3-CONTROLLER: Fix for IRIG sync frequency jump
* TRION3-CONTROLLER: Fix for Frequency Out doesn't work
* TRION3-CONTROLLER: Fix for PTP-Master cold start - invalid sync signal
* TRION3-POWER: Wrong measurement on SUB-XV @3MS
* TRION3-POWER: Fix for spikes on Channels
* TRION-1620-LV/ACC: Fix for DCDC Control fails
* TRION3-POWER & TRION-SUB-CT: Fix for Offset Jumps between several restarts.
* TRION-SUB-XV: Fix for wrong measurement scaling

DEWETRON-TRION-Applications-7.7.1.8228.exe
EXE309.89 MB
DEWETRON-TRION-Applications-7.7.1.8228.exe
md5: e2fed2176cba908e6c6923320ae5553d
R7.7.1
OS Compatibility: Windows
Notes for DEWETRON-TRION-Applications-7.7.1.8228.exe

## 2025-11-27 Release Notice DEWETRON TRION API R7.7.1

Revision: 3291af01d8efa69078acc73564d0367fa20e278f 

Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 7.7.1.8228
DEWETRON TRION API              | 7.7.1.8228
DEWETRON TRION driver           | 7.7.1.8228
DEWETRON DEWE2 driver           | 7.7.1.8228

## Files
DEWETRON-TRION-Applications-7.7.1.8228.exe

## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.7.1 or higher
* Windows 10 64-Bit or better

## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade

## Fixes and Changes
* Fixed the TRION-SUB-XV DC-Accuracy Problem with firmware 0084 [ID015]

## New Firmwares

HW Support TRION3 modules       | Firmware
--------------------------------|-----------
TRION3-1810-HV-8                | FW: 0085
TRION3-1810-POWER-4-V2          | FW: 0085
TRION3-1810M-POWER-4            | FW: 0085
TRION3-1810M-POWER-4-V2         | FW: 0085
TRION3-1820-POWER-4             | FW: 0085
TRION3-1820-POWER-4-V2          | FW: 0085

HW Support TRION modules        | Firmware
--------------------------------|-----------
TRION-1810-HV-4                 | FW: 0085
TRION-1810-HV-8                 | FW: 0085
TRION-1810M-POWER-4             | FW: 0085
TRION-1820-POWER-4              | FW: 0085

HW Support LITE[PA] modules     | Firmware
--------------------------------|-----------
LITEPA-4                        | FW: 0085

DEWETRON-TRION-Applications-8.0.0.9068.exe
EXE278.04 MB
DEWETRON-TRION-Applications-8.0.0.9068.exe
md5: 5283c71edc4420c495a2b3023106b6f2
R8.0.0
OS Compatibility: Windows
Notes for DEWETRON-TRION-Applications-8.0.0.9068.exe


## 2026-02-19 Release Notice DEWETRON TRION API R8.0.0
Revision: 5b377c100c887e7f4e18b1736b9f4c679e8f1d57
Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 8.0.0.9068
DEWETRON TRION API              | 8.0.0.9068
DEWETRON TRION driver           | 8.0.0.9068
DEWETRON DEWE2 driver           | 8.0.0.9068
## Files
DEWETRON-TRION-Applications-8.0.0.9068.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R8.0.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-CONTROLLER: Added support for gPTP (IEEE 802.1AS)
* TRION3-24XX-ACC, TRION3-24XX-LV support added
* NEXDAQ: Fixed an issue, where CAN-FD-Frames would only correctly transmit the first 8 bytes of a message
* NEXDAQ-1000: CNT1 to CNT4 can now be used with 1MS, avoiding artifacts in frequency-measurement due to sample-reduction

## New Firmwares
HW Support TRION3 modules       | Firmware
--------------------------------|-----------
TRION3-2402-ACC-6-BNC           | FW: 0021
TRION3-2420-ACC-6-BNC           | FW: 0021
TRION3-2402-LV-6-BNC            | FW: 0021
TRION3-2420-LV-6-BNC            | FW: 0021
TRION3-CONTROLLER               | FW: 0052   MCU: 01000161

HW Support Chassis modules      | Firmware
--------------------------------|-----------
TRION3-CONTROLLER               | FW: 0052   MCU: 01000161

 

DEWETRON-TRION-Applications-8.1.0.9904.exe
EXE311.28 MB
DEWETRON-TRION-Applications-8.1.0.9904.exe
md5: 6546d0e5e56be1b6e771ec6e3391d6ca
R8.1.0
OS Compatibility: Windows
Notes for DEWETRON-TRION-Applications-8.1.0.9904.exe


## 2026-05-13 Release Notice DEWETRON TRION API R8.1.0
Revision: 528f98f6e62d43db3922896b81cf7ea97c8d3638
Components                      | Version
--------------------------------|--------------------------
DEWETRON Explorer               | 8.1.0.9904
DEWETRON TRION API              | 8.1.0.9904
DEWETRON TRION driver           | 8.1.0.9904
DEWETRON DEWE2 driver           | 8.1.0.9904
## Files
DEWETRON-TRION-Applications-8.1.0.9904.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R8.1.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRION3-SUB8: Fixed a phase shift between TRION3-18XX-POWER and SUB8 when using SUB-XV modules.
* TRION3-24XX-ACC: Fixed a temperature dependent issue on CH6
* TRION3-24XX-ACC: Fixed an issue when sometimes the acquisition start was delayed.
* TRION3-CONTROLLER: Fixed an issue when as PTP Master the UTC Offset could not be set.
## New Firmwares
HW Support TRION3 modules       | Firmware
--------------------------------|-----------
TRION3-1810-SUB-8               | FW: 0021
TRION3-1810M-SUB-8              | FW: 0021
TRION3-1820-SUB-8               | FW: 0021
TRION3-2402-ACC-6-BNC           | FW: 0024
TRION3-2402-LV-6-BNC            | FW: 0024
TRION3-2420-ACC-6-BNC           | FW: 0024
TRION3-2420-LV-6-BNC            | FW: 0024
HW Support Chassis modules      | Firmware
--------------------------------|-----------
TRION3-CONTROLLER               | FW: 0053   MCU: 01010161
HW Support LITE[PA] modules     | Firmware
--------------------------------|-----------
LITEPA-CONTROLLER               | FW: 0053

 

DEWE3-A8/A12/A8-PA Technical-Reference
PDF8.83 MB
DEWE3-A8-A12-A8-PA_Technical-Reference_101ex.pdf
md5: 0c47adf4705e38c778b274f878ec962a
1.0.1
Language: English