Skip to content
DEWETRON Customer Care Center

Accredited calibration

Find a detailed calibration description (points per range) / sample calibration reports for your product below. If the product you are looking for is not listed please contact support@dewetron.com

Please note our scope of accreditation (CMCs)

Calibrations requiring a different scope of accreditation are performed by external partner calibration laboratories (accredited to ISO-17025). 

 
belongs to: Customer Care Center 
Accredited sample report for ACCRED-CAL-DEWE2-PW-1PH - TRION POWER + SUB-CT
PDF270 KB
TRION-Active-Power-1-Phase_CT_Akkred.pdf
md5: d9678b589c972e67d3a051b3ba650c02
2.20
Notes for Accredited sample report for ACCRED-CAL-DEWE2-PW-1PH - TRION POWER + SUB-CT

Pricelist item includes 1 phase

TRIONx-18xx-POWER + TRION-POWER-SUB-CT

calibration is perfomed with fixed phase combinations on a single board: U1-I1, U2-I2..

Accredited sample report for ACCRED-CAL-DEWE2-PW-1PH - TRION POWER + SUB-CUR-02A
PDF290 KB
TRION-Active-Power-1-4-Phase_Akkred_02A.pdf
md5: 4bd5d4afb53e990392f43313e1cfab4e
2.00
Notes for Accredited sample report for ACCRED-CAL-DEWE2-PW-1PH - TRION POWER + SUB-CUR-02A

Pricelist item includes 1 phase

TRIONx-18xx-POWER + TRION-POWER-SUB-CUR-02A-1

calibration is perfomed with fixed phase combinations on a single board: U1-I1, U2-I2..

Accredited sample report for ACCRED-CAL-DEWE2-PW-1PH - TRION POWER + SUB-CUR-1A
PDF293 KB
ACCRED-CAL-DEWE2-PW-1PH_Active_Power_TRIONx-18xx-POWER_TRION-SUB-CUR-1A.pdf
md5: 237d0cabb76b3d41b5c95cff412b41a6
2.00
Notes for Accredited sample report for ACCRED-CAL-DEWE2-PW-1PH - TRION POWER + SUB-CUR-1A

Pricelist item includes 1 phase

TRIONx-18xx-POWER + TRION-POWER-SUB-CUR-1A-1

calibration is perfomed with fixed phase combinations on a single board: U1-I1, U2-I2..

Accredited sample report for ACCRED-CAL-DEWE2-PW-1PH - TRION POWER + SUB-CUR-20A
PDF266 KB
TRION-Active-Power-1-Phase_20A_Akkred.pdf
md5: 6f3665137e98c49d78ec63d28741f739
2.00
Notes for Accredited sample report for ACCRED-CAL-DEWE2-PW-1PH - TRION POWER + SUB-CUR-20A

Pricelist item includes 1 phase

TRIONx-18xx-POWER + TRION-POWER-SUB-CUR-20A-1

calibration is perfomed with fixed phase combinations on a single board: U1-I1, U2-I2..

Accredited sample report for ACCRED-CAL-DEWE2-PW-1PH - TRION POWER + SUB-CUR-2A
PDF297 KB
ACCRED-CAL-DEWE2-PW-1PH_Active_Power_TRIONx-18xx-POWER_TRION-SUB-CUR-2A.pdf
md5: 1215be856958e143c6d20dbdef63bb6c
2.00
Notes for Accredited sample report for ACCRED-CAL-DEWE2-PW-1PH - TRION POWER + SUB-CUR-2A

Pricelist item includes 1 phase

TRIONx-18xx-POWER + TRION-POWER-SUB-CUR-2A-1

calibration is perfomed with fixed phase combinations on a single board: U1-I1, U2-I2..

Accredited sample report for CPAD3-TH8-T
PDF254 KB
CPAD3-TH8-T_Akkred.pdf
md5: fe7fa8efe406be13725511efdf6ca53f
1.00
Accredited sample report for CPAD3-TH8-UNIVERSAL
PDF248 KB
CPAD3-TH8-UNIVERSAL_Akkred.pdf
md5: f22b1598a0704533caaea8dc3dfa839d
2.00
Accredited sample report for DAQP-ACC-A
PDF248 KB
DAQP-ACC-A_Akkred.pdf
md5: 8a06f4689bb9f5cd8a6724c9bfdc358d
2.00
Accredited sample report for DAQP-HV
PDF255 KB
DAQP-HV_Akkred.pdf
md5: 87363be67afcffc8da2ba9f751dc5106
2.00
Notes for Accredited sample report for DAQP-HV

also valid for HSI-HV modules - similar testpoints

Accredited sample report for DAQP-LV
PDF266 KB
DAQP-LV_Akkred.pdf
md5: dbda5fd36b5df8ef27376e703f88cd3c
2.00
Accredited sample report for DAQP-STG
PDF258 KB
DAQP-STG_Akkred.pdf
md5: 6a67d1099c6f8962ef3ddef249070028
2.00
Accredited sample report for DAQP-V-B
PDF265 KB
DAQP-V-B_Akkred.pdf
md5: 92364a9219ca2e841d3fa7cc5f1cc8ef
2.00
Accredited sample report for DEWE SUNT-PM-MCTS-BR5
PDF259 KB
DEWE_SHUNT_PM-MCTS-BR5_Akkred.pdf
md5: 9ba26ec75759922c0f973e34e357cee0
1.00
Accredited sample report for DEWE-50-USB-8
PDF273 KB
DEWE-50-USB-8_Akkred_Cert.pdf
md5: c06445b28139443b92830624285a2ab4
2.00
Notes for Accredited sample report for DEWE-50-USB-8

also valid for all devices with DEWE-43 hardware

Accredited sample report for DEWE-RACK
PDF269 KB
DEWE-RACK_Akkred_ORION-xx24-xxx.pdf
md5: 038f0629a286352c41f2fa34197d8995
2.00
Notes for Accredited sample report for DEWE-RACK

sample report for all DEWE-Rack series

testpoints, specifications, samplerates, channel count may vary due to different AD board types

limits may contain additional specs for module-backplane / limits may were set by lab due to lack of specification by manufacturer

Accredited sample report for EPAD/CPAD-TH8-U
PDF251 KB
xPAD2-TH8-UNIVERSAL_Akkred.pdf
md5: 82eb1843054d4023daa13061c5dc64f1
2.10
Notes for Accredited sample report for EPAD/CPAD-TH8-U

Calibration is done for type K

Accredited sample report for EPAD2-LA8-L1B
PDF254 KB
xPAD2-LA-L1B_Akkred.pdf
md5: 2eccb4942bb82d05866b58c631c8f91f
2.00
Notes for Accredited sample report for EPAD2-LA8-L1B

auch EPAD2-LA8-L1B

Accredited sample report for EPAD2-TH-8-K
PDF251 KB
xPAD2-TH8-K_Akkred.pdf
md5: c86924c782159553e44369ce73dde16e
2.10
Notes for Accredited sample report for EPAD2-TH-8-K

also valid for CPAD2-TH8-K

Accredited sample report for EPAD2-TH-8-T
PDF251 KB
xPAD2-TH8-T_Akkred.pdf
md5: 944d27086f54ab320b434442ac63f4e2
2.10
Notes for Accredited sample report for EPAD2-TH-8-T

also valid for CPAD2-TH8-T

Accredited sample report for LITE-PA-4
PDF264 KB
LITEPA-4_akkred.pdf
md5: a8c03a3a28e21f7edea4dcd2272b66d4
2.00
Accredited sample report for MDAQ-SUB-STG/BRIDGE
PDF291 KB
MDAQ-SUB-STG_BRIDGE_Akkred.pdf
md5: 313a57eb8838a6f5456e53a9efd89705
2.00
Accredited sample report for MSI-BR-ACC
PDF249 KB
MSI-BR-ACC_Akkred.pdf
md5: dccb49731bf9e955cd1f8aa4f6e6effb
1.00
Accredited sample report for MSI-BR-RTD
PDF241 KB
MSI-BR-RTD_Akkred.pdf
md5: 9b8be0bed86732ef37de3f2953b006c0
1.00
Accredited sample report for MSI-BR-TH-K
PDF252 KB
MSI-BR-TH-K_Akkred.pdf
md5: de87aff8a9f160bebfdf35b13f588997
2.00
Accredited sample report for MSI-BR-V-200
PDF253 KB
MSI-BR-V-200_Akkred.pdf
md5: b2588dfeea5414b42dffdbe84d496ce6
2.00
Accredited sample report for MSI-BR-V-600
PDF255 KB
MSI2-V-600_Akkred.pdf
md5: efb54cc2088f802cf972849e956d8db3
1.00
Accredited sample report for MSI-V-ACC
PDF249 KB
MSI-V-ACC_Akkred.pdf
md5: 002f19c13d6e729dbe437ca3b2fff2c1
2.00
Accredited sample report for MSI2-LA-250R-20mA
PDF251 KB
MSI2-LA-250R-20mA_Akkred.pdf
md5: 650243907c8182ea0c090293d92afb46
2.00
Accredited sample report for MSI2-TH-K
PDF252 KB
MSI2-TH-K_Akkred.pdf
md5: 37b0ff509fb5c68ec4a040c4df138e68
2.00
Accredited sample report for MSI2-TH-T
PDF252 KB
MSI2-TH-T_Akkred.pdf
md5: 30636f0a850e096f40634361a7e8028b
1.01
Accredited sample report for NEXDAQ-200/NEXDAQ-1000
PDF286 KB
NEXDAQ_Akkred.pdf
md5: 7f54114d6a30c1459668e1de786194d4
2.01
Accredited sample report for PAD-CB8-K
251 KB
PAD-CB8-K_Akkred
md5: faee3daf79b409b0af993b0521ae2fed
2.10
Accredited sample report for PAD-CB8-RTD
PDF265 KB
CB8-RTD_Akkred.pdf
md5: 5826516343cd9cf657360e63ea8b188b
1.10
Notes for Accredited sample report for PAD-CB8-RTD

also valid for:

PAD-CB8-RTD-V3

scope of testpoints can be slightly different due to other SPECS

 

Accredited sample report for PUREC-50/200
PDF281 KB
PUREC-xxx-System-Akkred.pdf
md5: 03c97543357cf44c45f8a0f0bafd8877
2.0
Accredited sample report for SE-CUR-SHUNT-05
PDF257 KB
SE-CUR-SHUNT-05_Akkred.pdf
md5: 58662717b7e5422469b301a9acf72891
2.00
Accredited sample report for SE-CUR-SHUNT-06
PDF253 KB
SE-CUR-SHUNT-06_Akkred.pdf
md5: fb907ec1addbc99a52d4f883fa3f681b
1.00
Accredited sample report for TRION-16xx
PDF304 KB
TRION-16xx_Akkred_1620-LV.pdf
md5: c1e47b80eea74b8ef6d052bbd2b98a69
2.0
Notes for Accredited sample report for TRION-16xx

also valid for other TRION-16xx boards

scope of testpoints can be slightly different due to other specifications and functions

additional for L1B versions:

Current measurement: at least 2 DC and 3 AC testpoints per range

Voltage excitation: at least 5 DC testpoints

 

Accredited sample report for TRION-1802/1600-dLV
PDF321 KB
TRION-1802_1600-dLV_Akkred.pdf
md5: ddbe480bb2f12fa7141e4629f83fc18f
2.00
Notes for Accredited sample report for TRION-1802/1600-dLV

testpoints can be slightly different due to the specs of the boards

Accredited sample report for TRION-18xx-MULTI-x
PDF298 KB
TRION-18xx-MULTI_Akkred.pdf
md5: b586bb62cb69ef6b5e31accab2faaae8
2.11
Notes for Accredited sample report for TRION-18xx-MULTI-x

sample report for TRION/TRION3-18xx-MULTI-x series

testpoints can be slightly different due to the specs of the boards

Accredited sample report for TRION-2402-dACC
PDF303 KB
TRION-2402-dACC_Akkred.pdf
md5: 03c10e1dc67aeb5719f12e3baa8c5f77
2.00
Accredited sample report for TRION-2402-MULTI
PDF298 KB
TRION-2402-MULTI_Akkred.pdf
md5: 0db4ef82d7b47105e44ad08e1628d5c5
2.10
Accredited sample report for TRION-2402-V
PDF298 KB
TRION-2402-V_Akkred.pdf
md5: ed1df78ae3d0d894e139106e2e77fdb3
2.00
Accredited sample report for TRION-240x-dSTG
PDF310 KB
TRION-240x-dSTG_Akkred.pdf
md5: 3d0350c273a28193adfe84253e2274cf
2.00
Accredited sample report for TRION-SUB-5V
PDF251 KB
TRION-SUB-xxxV_Akkred_5V.pdf
md5: fbd56569bdfe476050a67b3e58d8b1ee
2.00
Accredited sample report for TRION-SUB-600V
PDF252 KB
TRION-SUB-xxxV_Akkred_600V.pdf
md5: a72ef7c6b3666db580baf59c8856252e
2.00
Accredited sample report for TRION-SUB-CT
PDF259 KB
TRION-SUB-CT_Akkred.pdf
md5: 167e1586c759a98e89cba02c33e0b94b
2.0
Accredited sample report for TRION-SUB-CUR-x
PDF251 KB
TRION-SUB-CUR-x_Accred.pdf
md5: fabcfa792be7a93bdcfbde01e1ad95f3
2.00
Notes for Accredited sample report for TRION-SUB-CUR-x

testpoint and limits may vary due to different SUB-CUR types

Accredited sample report for TRION-SUB-dLV-1V
PDF251 KB
TRION-SUB-xxxV_Akkred_dLV-1V.pdf
md5: b4f6c1affe10d3e19298e498ee4ff76c
2.00
Accredited sample report for TRION-SUB-dLV-5V
PDF252 KB
TRION-SUB-xxxV_Akkred_dLV-5V.pdf
md5: 5f45d1044c110fbc8e38feec6ee49c4c
2.00
Accredited sample report for TRION-SUB-XV
PDF253 KB
TRION-SUB-xxxV_Akkred_XV.pdf
md5: 200ca56c732daef37613c74beb7bc8b5
2.00
Accredited sample report for TRION/TRION3-18xx-POWER and TRION/TRION3-1810-HV series
PDF264 KB
TRION-18xx-HV_POWER_Akkred.pdf
md5: a1b3ba0e0f5898603e39300568bf6504
2.00
Notes for Accredited sample report for TRION/TRION3-18xx-POWER and TRION/TRION3-1810-HV series

Sample report is valid for all types of TRION/TRION3-18xx-POWER series and 1810-HV series

Samplerate and testpoints may differ slightly between board types

Accredited sample report for TRION3-24xx-ACC/LV series boards
PDF284 KB
TRION3-24xx-ACC-LV_Akkred_2420-ACC.pdf
md5: 084461bd0b4e22462bffc86c8b7f110b
2.00
Notes for Accredited sample report for TRION3-24xx-ACC/LV series boards

Testpoints may vary due to board variant

Accredited sample report for TRION3-AOUT-8
PDF272 KB
TRION3-AOUT-8_Akkred.pdf
md5: 5c9cde8e9655e4d33ae030ee150e0f99
2.00
Accredited sample report for xPAD2-RTD
PDF275 KB
xPAD2-RTD_Akkred.pdf
md5: 9a3b441b86ccf8b10dc2137e85b345c1
1.00
Accredited sample report for xPAD2-TH8-P
PDF253 KB
xPAD2-TH8-P_Akkred.pdf
md5: e519e4fc5053f762662eea1c626931c5
1.00
Accredited sample report for xPAD2-V8 / CPAD3-V8 / PAD-V8-P
PDF268 KB
xPAD2-V8.pdf
md5: ad3d74c2c6f88720ddc5db0da2a40131
2.00
Accredited sample report for XR-RTD8
PDF264 KB
XR-RTD8_Akkred.pdf
md5: 0b803356620f06a55b87c88375071a57
2.10
Accredited sample report for XR-TH8
PDF261 KB
XR-TH8_Akkred.pdf
md5: 6d3a9c3f1f49ee302e79284a8d9a84e3
2.10
Accredited sample report for XR-V8
PDF257 KB
XR-V8_Akkred.pdf
md5: cd5ca8995db6be478eb405ba5213a0fc
2.00
Accredited calibration brochures
PDF2.55 MB
accred-cal-brochures_g.pdf
md5: 3e18f6c7189d535a61623707c341316c
1.0
Language: German
ISO 17025 Certificate Austria
PDF364 KB
iso-17025_dewetron_certificate_AUSTRIA.pdf
md5: 22411d79d4c9a95e0b95a0349688af8a
Language: German/English
ISO 17025 certificate by ANAB (until 2027-06)
PDF492 KB
DEWETRON-ANAB-ISO17025-until-06-27.pdf
md5: 184854c25e8a444e8e6b448536868cac
2025-2027
2025/06
Language: English US
ISO 17025 CMC Austria
PDF296 KB
iso-17025_dewetron_cmc_AUSTRIA.pdf
md5: 8f5ebcefa0a962ae5fe19ba1b94f0f5a
ISO 9001 Certificate for USA - PRI Certification (until 2028)
PDF292 KB
iso-9001-dewetron-USA.pdf
md5: 039f07c36f5f26598534e0043b0d0448
2025-2028
2025/01
Language: English US
ISO 9001/14001 Certificate (until 2029)
PDF969 KB
iso-9001_iso-14001_dewetron_e.pdf
md5: 30decc4e30d8aea881c63ae4b6221f0a
2026-2029
2026/09
Language: English
ISO 9001/14001 Zertifikat (bis 2029)
PDF969 KB
iso-9001_iso-14001_dewetron_g.pdf
md5: 2e898b0c0e714b47fa6b207076a2c355
2026-2029
2026/09
Language: German
ACCRED-CAL-DAQX-X
PDF8 KB
ACCRED-CAL-DAQX-X.pdf
md5: 9f645a8ba2c267c1dfc817b1f647dff2
1.0
Language: English / Deutsch
ACCRED-CAL-HSI-X
PDF7 KB
ACCRED-CAL-HSI-X.pdf
md5: 057015d47de92beea0cb4a328552bcfc
1.0
Language: English / Deutsch
ACCRED-CAL-PAD-X
PDF6 KB
ACCRED-CAL-PAD-X.pdf
md5: f13b8343239fc48136130508eb88a42f
1.0
Language: English / Deutsch
ACCRED-CAL-TRION-X
PDF7 KB
ACCRED-CAL-TRION-X.pdf
md5: f57efeb1be0b37f27e08cf225eae00b4
1.0
Language: English / Deutsch
ACCRED-CAL-CB8-X
PDF7 KB
ACCRED-CAL-CB8-X.pdf
md5: af8501d57ff188f09a58242203e547a0
1.0
Language: English / Deutsch
ACCRED-CAL-DAQ-RACK-X
PDF8 KB
ACCRED-CAL-DAQ-RACK-X.pdf
md5: ded5ae1c073655f1636ed28bb4111302
1.0
Language: English / Deutsch
ACCRED-CAL-XPAD-X
PDF7 KB
ACCRED-CAL-XPAD-X.pdf
md5: 78678f5308535a58175730cf92848f6f
1.0
Language: English / Deutsch
ACCRED-CAL-MDAQ-X
PDF8 KB
ACCRED-CAL-MDAQ-X.pdf
md5: 5a246b3e0b01277da6230c8218f9eaca
1.0
Language: English / Deutsch
ACCRED-CAL-MSI-X
PDF7 KB
ACCRED-CAL-MSI-X.pdf
md5: ff37e8fe23c9a45242dad7b3a93ff1dc
1.0
Language: English / Deutsch
ACCRED-CAL-ORION-X
PDF8 KB
ACCRED-CAL-ORION-X.pdf
md5: 6e4b6a8d61a3f967e6cd2ad693c81359
1.0
Language: English / Deutsch
ACCRED-CAL-DA-X
PDF7 KB
ACCRED-CAL-DA-X.pdf
md5: ccc6e6d069f99863eba31ddd1102aa58
1.0
Language: English / Deutsch
ACCRED-CAL-M2i-X
PDF7 KB
ACCRED-CAL-M2i-X.pdf
md5: 9a79ed8f52951b5875101c544655bb3f
1.0
Language: English / Deutsch
ACCRED-CAL-DEWE-43_101
PDF7 KB
ACCRED-CAL-DEWE-43_101.pdf
md5: a3fedb36bbe6c0cbad004c2e234a44a7
1.0
Language: English / Deutsch
ACCRED-CAL-SHUNT-x-DC
PDF187 KB
ACCRED-CAL-SHUNT-x-DC.pdf
md5: e88df0650b1d76dcf24eda5c1891b30a
1.0
Language: English / Deutsch