Measurement systems for your PC via Ethernet or USB
Connect DEWETRON’s front-end systems to your computer via USB or Ethernet interface, to become a powerful data acquisition system. The systems are distributable and can be daisy-chained to a multi-channel measurement system. Every common sensor is supported by using our special MSI sensor adapters.
## 2025-03-05 Release Notice DEWETRON Frontend Firmware R7.4.2
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
Revision: 38d9842531ceafe409e38f55812f2da2aa53be1a
Components | Version
--------------------------------|--------------------------
OS | Yocto kirkstone-4.0.18
DEWETRON TRIONet Server | 7.4.2.7598
DEWETRON TRION API | 7.4.2.7598
DEWETRON TRION driver | 7.4.2.7598
## Files
### DEWE3 Frontend remote update
frontend_swupdate_7.4.2.7598_279.swu
### DEWE3 Frontend USB stick image
frontend_update_stick_image_7.4.2.7598_279.img.zip
## Fixes and Changes
* TRIONet API returned an invalid number of samples when using i64 getter function
FRONTEND Firmware R7.4.2: Update files for existing USB stick
(02_FRONTEND_R7.4.2_Update_existing_USB-stick.zip - 289.97 MB) md5: 358d9fb24c67127002c431b04e37115c
## 2025-03-05 Release Notice DEWETRON Frontend Firmware R7.4.2
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
Revision: 38d9842531ceafe409e38f55812f2da2aa53be1a
Components | Version
--------------------------------|--------------------------
OS | Yocto kirkstone-4.0.18
DEWETRON TRIONet Server | 7.4.2.7598
DEWETRON TRION API | 7.4.2.7598
DEWETRON TRION driver | 7.4.2.7598
## Files
### DEWE3 Frontend remote update
frontend_swupdate_7.4.2.7598_279.swu
### DEWE3 Frontend USB stick image
frontend_update_stick_image_7.4.2.7598_279.img.zip
## Fixes and Changes
* TRIONet API returned an invalid number of samples when using i64 getter function
## 2025-03-05 Release Notice DEWETRON Frontend Firmware R7.4.2
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
Revision: 38d9842531ceafe409e38f55812f2da2aa53be1a
Components | Version
--------------------------------|--------------------------
OS | Yocto kirkstone-4.0.18
DEWETRON TRIONet Server | 7.4.2.7598
DEWETRON TRION API | 7.4.2.7598
DEWETRON TRION driver | 7.4.2.7598
## Files
### DEWE3 Frontend remote update
frontend_swupdate_7.4.2.7598_279.swu
### DEWE3 Frontend USB stick image
frontend_update_stick_image_7.4.2.7598_279.img.zip
## Fixes and Changes
* TRIONet API returned an invalid number of samples when using i64 getter function
FRONTEND Firmware R6.7.3: Create new USB update stick
(01_FRONTEND_R6.7.3_Create_USB-stick.zip - 294.42 MB) md5: 03c45568fca18013ae407752ac0dd89f
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## New Features and most important bugfixes:
* TRIONet3 device support
* TRION(3)-1820-MULTI:
* Input coupling (highpass filter) overshoot fixed with 0.15Hz filter
* TRION(3)-Power:
* TRION SUB-XV support added
* TRION3-SUB-8:
* TRION SUB-XV support added
## Known Limitations
* Only one ethernet port usable.
FRONTEND Firmware R6.7.1: Create new USB update stick
(01_FRONTEND_R6.7.1_Create_USB-stick.zip - 289.15 MB) md5: 6bc7e1ee6ef25ce45995d082f3f26fca
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* IP Config: Set factory default IP address to DHCP with autoip (LL) fallback
* TRION driver fix for last 32bit addressable page (Debian Linux OS)
## Known Limitations
* Only one ethernet port usable.
FRONTEND Firmware R6.7.2: Create new USB update stick
(01_FRONTEND_R6.7.2_Create_USB-stick.zip - 291.81 MB) md5: 7663b9728feaf904107132edc8969994
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes
* TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal
* trion_cal: TRION-18XX-MULTI, allow AUTO and 0Hz for HP-Filter in XML
* CHASSIS-CONTROLLER-V2: Fixed an issue with spikes when using CAN OUT (new fw)
## Known Limitations
* ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
FRONTEND Firmware R7.0.0: Create new USB update stick
(01_FRONTEND_R7.0.0_Create_USB-stick.zip - 295.43 MB) md5: ed3336b0a98d2ddfa8c3969523606b93
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* Allow device network configuration even if ip settings do not match
* Node default name is the serial number
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## 2024-11-20 Release Notice DEWETRON Frontend Firmware R7.3.2
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
Revision: f6f8bf5b1b38b78b8d8a67761130412adeb7e977
Components | Version
--------------------------------|--------------------------
OS | Yocto kirkstone-4.0.18
DEWETRON TRIONet Server | 7.3.2.6198
DEWETRON TRION API | 7.3.2.6198
DEWETRON TRION driver | 7.3.2.6198
## Files
### DEWE3 Frontend remote update
frontend_swupdate_7.3.2.6198_252.swu
### DEWE3 Frontend USB stick image
frontend_update_stick_image_7.3.2.6198_252.img.zip
## Fixes
* Fix for semaphore handling of date and time changes.
FRONTEND Firmware R7.4.1: Create new USB update stick
(01_FRONTEND_R7.4.1_Create_USB-stick.zip - 312.80 MB) md5: 951677b5c24f30c06356d2d00751da63
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* Allow device network configuration even if ip settings do not match
* Node default name is the serial number
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## 2024-11-20 Release Notice DEWETRON Frontend Firmware R7.3.2
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
Revision: f6f8bf5b1b38b78b8d8a67761130412adeb7e977
Components | Version
--------------------------------|--------------------------
OS | Yocto kirkstone-4.0.18
DEWETRON TRIONet Server | 7.3.2.6198
DEWETRON TRION API | 7.3.2.6198
DEWETRON TRION driver | 7.3.2.6198
## Files
### DEWE3 Frontend remote update
frontend_swupdate_7.3.2.6198_252.swu
### DEWE3 Frontend USB stick image
frontend_update_stick_image_7.3.2.6198_252.img.zip
## Fixes
* Fix for semaphore handling of date and time changes.
FRONTEND Firmware R7.4.1: Update files for existing USB stick
(02_FRONTEND_R7.4.1_Update_existing_USB-stick.zip - 284.19 MB) md5: 50ace8a4de2c78c0095ea66e0574bacf
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* Allow device network configuration even if ip settings do not match
* Node default name is the serial number
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## 2024-11-20 Release Notice DEWETRON Frontend Firmware R7.3.2
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
Revision: f6f8bf5b1b38b78b8d8a67761130412adeb7e977
Components | Version
--------------------------------|--------------------------
OS | Yocto kirkstone-4.0.18
DEWETRON TRIONet Server | 7.3.2.6198
DEWETRON TRION API | 7.3.2.6198
DEWETRON TRION driver | 7.3.2.6198
## Files
### DEWE3 Frontend remote update
frontend_swupdate_7.3.2.6198_252.swu
### DEWE3 Frontend USB stick image
frontend_update_stick_image_7.3.2.6198_252.img.zip
## Fixes
* Fix for semaphore handling of date and time changes.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* TRION3-1820-MULTI, TRION3-1850-MULTI
- Current mode: 2mA range support added
* TRION-1820-MULTI
- Current mode: 2mA range support added
## Known Limitations
* Only one ethernet port usable.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* Fixed an issue when TRIONet device wre not shown after changing IP settings
## New Features and most important bugfixes:
* TRION3-18XX-MULTI, TRION-18XX-MULTI higher sensor excitation power
- up to 1W for 24V setting
* TRION3-1802-dLV: Full support added
* TRION3-1600-dLV: Full support added
## Known Limitations
* Only one ethernet port usable.
FRONTEND Firmware R6.3.0: Update files for existing USB stick
(02_FRONTEND_R6.3.0_Update_existing_USB-stick.zip - 190.30 MB) md5: 5caa5a821cc3da3807ee5b9a2cfc2fc8
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* TRION3-1820-MULTI, TRION3-1850-MULTI
- Current mode: 2mA range support added
* TRION-1820-MULTI
- Current mode: 2mA range support added
## Known Limitations
* Only one ethernet port usable.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* Fixed an issue when TRIONet device wre not shown after changing IP settings
## New Features and most important bugfixes:
* TRION3-18XX-MULTI, TRION-18XX-MULTI higher sensor excitation power
- up to 1W for 24V setting
* TRION3-1802-dLV: Full support added
* TRION3-1600-dLV: Full support added
## Known Limitations
* Only one ethernet port usable.
FRONTEND Firmware R6.6.0: Update files for existing USB stick
(02_FRONTEND_R6.6.0_Update_existing_USB-stick.zip - 253.65 MB) md5: 74db96a33fae27c653bc0f3b6efcd974
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## New Features and most important bugfixes:
* TRIONet3 device support
* TRION(3)-1820-MULTI:
* Input coupling (highpass filter) overshoot fixed with 0.15Hz filter
* TRION(3)-Power:
* TRION SUB-XV support added
* TRION3-SUB-8:
* TRION SUB-XV support added
## Known Limitations
* Only one ethernet port usable.
FRONTEND Firmware R6.7.1: Update files for existing USB stick
(02_FRONTEND_R6.7.1_Update_existing_USB-stick.zip - 260.55 MB) md5: e0f13f738de7a571f5a4f2cd96b69309
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* IP Config: Set factory default IP address to DHCP with autoip (LL) fallback
* TRION driver fix for last 32bit addressable page (Debian Linux OS)
## Known Limitations
* Only one ethernet port usable.
FRONTEND Firmware R6.7.2: Update files for existing USB stick
(02_FRONTEND_R6.7.2_Update_existing_USB-stick.zip - 263.21 MB) md5: bcd78e8bc86746f92fc81a89e151772c
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes
* TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal
* trion_cal: TRION-18XX-MULTI, allow AUTO and 0Hz for HP-Filter in XML
* CHASSIS-CONTROLLER-V2: Fixed an issue with spikes when using CAN OUT (new fw)
## Known Limitations
* ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* TRION3-1820-MULTI, TRION3-1850-MULTI
- Current mode: 2mA range support added
* TRION-1820-MULTI
- Current mode: 2mA range support added
## Known Limitations
* Only one ethernet port usable.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* Fixed an issue when TRIONet device wre not shown after changing IP settings
## New Features and most important bugfixes:
* TRION3-18XX-MULTI, TRION-18XX-MULTI higher sensor excitation power
- up to 1W for 24V setting
* TRION3-1802-dLV: Full support added
* TRION3-1600-dLV: Full support added
## Known Limitations
* Only one ethernet port usable.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## New Features and most important bugfixes:
* TRIONet3 device support
* TRION(3)-1820-MULTI:
* Input coupling (highpass filter) overshoot fixed with 0.15Hz filter
* TRION(3)-Power:
* TRION SUB-XV support added
* TRION3-SUB-8:
* TRION SUB-XV support added
## Known Limitations
* Only one ethernet port usable.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes:
* IP Config: Set factory default IP address to DHCP with autoip (LL) fallback
* TRION driver fix for last 32bit addressable page (Debian Linux OS)
## Known Limitations
* Only one ethernet port usable.
## Description:
Software Release for selected DEWETRON DEWE3 enclosures allowing them
to operate like TRIONet devices including multiple frontends and TRION-SYNC.
Released for DEWE3-RMx and DEWE3-Mx.
## Requirements
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release
## New Features and most important bugfixes
* TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal
* trion_cal: TRION-18XX-MULTI, allow AUTO and 0Hz for HP-Filter in XML
* CHASSIS-CONTROLLER-V2: Fixed an issue with spikes when using CAN OUT (new fw)
## Known Limitations
* ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected
## 2025-03-05 Release Notice DEWETRON TRION API R7.4.2
Revision: 38d9842531ceafe409e38f55812f2da2aa53be1a
Components | Version
--------------------------------|--------------------------
DEWETRON Explorer | 7.4.2.7598
DEWETRON TRION API | 7.4.2.7598
DEWETRON TRION driver | 7.4.2.7598
DEWETRON DEWE2 driver | 7.4.2.7598
## Files
DEWETRON-TRION-Applications-7.4.2.7598.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.4.2 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRIONet API returned an invalid number of samples when using i64 getter function
* Removed prototype boards listed in DEWETRON Explorer
## 2025-03-05 Release Notice DEWETRON TRION API R7.4.2
Revision: 38d9842531ceafe409e38f55812f2da2aa53be1a
Components | Version
--------------------------------|--------------------------
DEWETRON Explorer | 7.4.2.7598
DEWETRON TRION API | 7.4.2.7598
DEWETRON TRION driver | 7.4.2.7598
DEWETRON DEWE2 driver | 7.4.2.7598
## Files
DEWETRON-TRION-Applications-7.4.2.7598.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.4.2 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* TRIONet API returned an invalid number of samples when using i64 getter function
* Removed prototype boards listed in DEWETRON Explorer
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.2.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes
* NEX[DAQ]-1000 simulation sample rate divider support fixed.
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.2.0 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes
* NEX[DAQ]-1000 simulation sample rate divider support fixed.
## 2024-11-20 Release Notice DEWETRON TRION API R7.3.2
Revision: f6f8bf5b1b38b78b8d8a67761130412adeb7e977
Components | Version
--------------------------------|--------------------------
DEWETRON Explorer | 7.3.2.6198
DEWETRON TRION API | 7.3.2.6198
DEWETRON TRION driver | 7.3.2.6198
DEWETRON DEWE2 driver | 7.3.2.6198
## Files
DEWETRON-TRION-Applications-7.3.2.6198.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.3.2 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes
* Fix for semaphore handling of date and time changes.
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.4.1 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* New firmware for 18XX-MULTI fixing spikes in the signal when using CAN OUT
## 2024-11-20 Release Notice DEWETRON TRION API R7.3.2
Revision: f6f8bf5b1b38b78b8d8a67761130412adeb7e977
Components | Version
--------------------------------|--------------------------
DEWETRON Explorer | 7.3.2.6198
DEWETRON TRION API | 7.3.2.6198
DEWETRON TRION driver | 7.3.2.6198
DEWETRON DEWE2 driver | 7.3.2.6198
## Files
DEWETRON-TRION-Applications-7.3.2.6198.exe
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.3.2 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes
* Fix for semaphore handling of date and time changes.
## Requirements
* Update all TRION modules to the latest firmware included in this release
* Use OXYGEN R7.4.1 or higher
* Windows 10 64-Bit or better
## Installation procedure
* Install TRION applications
* Reboot system (if requested by the installer)
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)
* Power-cycle TRION boards (Power down system, then restart)
* Start DEWETRON Explorer and check for a successful firmware upgrade
## Fixes and Changes
* New firmware for 18XX-MULTI fixing spikes in the signal when using CAN OUT
SELECT COUNT(*) AS `count` FROM `dewe_cakeisalie`.`productgroups` AS `Productgroup` WHERE `Productgroup`.`id` = 'frontend-series'
1
1
0
SELECT `Productgroup`.`id`, `Productgroup`.`slug`, `Productgroup`.`sort`, `Productgroup`.`description`, `Productgroup`.`name`, `Productgroup`.`productline_id`, `Productgroup`.`active`, `Productgroup`.`permissions`, `Productline`.`name`, `Productline`.`slug`, `Productline`.`id` FROM `dewe_cakeisalie`.`productgroups` AS `Productgroup` LEFT JOIN `dewe_cakeisalie`.`productlines` AS `Productline` ON (`Productgroup`.`productline_id` = `Productline`.`id` AND `Productline`.`active` = '1' AND (`Productline`.`permissions` & 1 != 0)) WHERE `Productgroup`.`active` = '1' AND (`Productgroup`.`permissions` & 1 != 0) AND `Productgroup`.`slug` = 'frontend-series' ORDER BY `Productline`.`sort` ASC, `Productline`.`name` ASC LIMIT 1
1
1
1
SELECT `Product`.`name`, `Product`.`slug`, `Product`.`id`, `Product`.`description`, `Product`.`productgroup_id` FROM `dewe_cakeisalie`.`products` AS `Product` WHERE `Product`.`active` = '1' AND (`Product`.`permissions` & 1 != 0) AND `Product`.`productgroup_id` = ('6502d956-d598-45f1-98e6-4a72d9c49a3c') ORDER BY `Product`.`sort` ASC, `Product`.`name` ASC
0
0
0
SELECT `Download`.`description`, `Download`.`advancedOnly`, `Download`.`internalOnly`, `Download`.`name`, `Download`.`id`, `Download`.`filesize`, `Download`.`version`, `Download`.`releasedate`, `Download`.`active`, `Download`.`downloadtype`, `Download`.`filename`, `Download`.`oscompat`, `Download`.`language`, `Download`.`md5`, `Download`.`sha1`, `DownloadsProductgroup`.`id`, `DownloadsProductgroup`.`download_id`, `DownloadsProductgroup`.`productgroup_id` FROM `dewe_cakeisalie`.`downloads` AS `Download` JOIN `dewe_cakeisalie`.`downloads_productgroups` AS `DownloadsProductgroup` ON (`DownloadsProductgroup`.`productgroup_id` = '6502d956-d598-45f1-98e6-4a72d9c49a3c' AND `DownloadsProductgroup`.`download_id` = `Download`.`id`) WHERE `Download`.`active` = '1' AND (`Download`.`permissions` & 1 != 0) ORDER BY `Download`.`downloadtype` ASC, `Download`.`sort` ASC, `Download`.`name` ASC
47
47
2
Query Explain:
Click an "Explain" link above, to see the query explanation.
description<p style="text-align:center"><img alt="" height="311" src="https://www.dewetron.com/app/uploads/2024/07/DEWE3-RMx_rack-mount-daq-system.png" width="501" /></p>
<h1><br />
<br />
Measurement systems for your PC via Ethernet or USB</h1>
<p>Connect DEWETRON’s front-end systems to your computer via USB or Ethernet interface, to become a powerful data acquisition system. The systems are distributable and can be daisy-chained to a multi-channel measurement system. Every common sensor is supported by using our special MSI sensor adapters.</p>
description<p><code>## 2023-10-23 Release Notice DEWETRON Frontend Firmware R6.7.1</code></p>
<p><code>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</code></p>
<p><code>Revision: 1ee33ea7162d4418af9de534a019b5426b815472</code></p>
<p><code>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto kirkstone-4.0.11<br />
DEWETRON TRIONet Server | 6.7.1.1582<br />
DEWETRON TRION API | 6.7.1.1582<br />
DEWETRON TRION driver | 6.7.1.1582</code></p>
<p><code>## Files<br />
### DEWE3 Frontend remote update<br />
frontend_swupdate_6.7.1.1582_109.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_6.7.1.1582_109.img.zip</code></p>
<p><code>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</code></p>
<p><code>## New Features and most important bugfixes:<br />
* IP Config: Set factory default IP address to DHCP with autoip (LL) fallback<br />
* TRION driver fix for last 32bit addressable page (Debian Linux OS)</code></p>
<p><code>## Known Limitations<br />
* Only one ethernet port usable.</code></p>
<p> </p>
advancedOnly(false)
internalOnly(false)
nameFRONTEND Firmware R6.7.1: Create new USB update stick
description<p><tt>## 2023-12-04 Release Notice DEWETRON Frontend Firmware R6.7.2</tt></p>
<p><tt>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</tt></p>
<p><tt>Revision: 6e29cade2bda4c122e6674a6263aeb6b6bb16c2c</tt></p>
<p><tt>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto kirkstone-4.0.11<br />
DEWETRON TRIONet Server | 6.7.2.2175<br />
DEWETRON TRION API | 6.7.2.2175<br />
DEWETRON TRION driver | 6.7.2.2175</tt></p>
<p><tt>## Files<br />
### DEWE3 Frontend remote update<br />
frontend_swupdate_6.7.2.2175_113.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_6.7.2.2175_113.img.zip</tt></p>
<p><tt>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</tt></p>
<p><tt>## New Features and most important bugfixes<br />
* TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal<br />
* trion_cal: TRION-18XX-MULTI, allow AUTO and 0Hz for HP-Filter in XML<br />
* CHASSIS-CONTROLLER-V2: Fixed an issue with spikes when using CAN OUT (new fw)</tt></p>
<p><tt>## Known Limitations<br />
* ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected</tt></p>
advancedOnly(false)
internalOnly(false)
nameFRONTEND Firmware R6.7.2: Create new USB update stick
description<p><code>## 2024-02-01 Release Notice DEWETRON Frontend Firmware R7.0.0</code></p>
<p><code>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</code></p>
<p><code>Revision: c8730c64bd0f421a4b0a87b70977e5b072fa9e1e</code></p>
<p><code>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto kirkstone-4.0.11<br />
DEWETRON TRIONet Server | 7.0.0.2733<br />
DEWETRON TRION API | 7.0.0.2733<br />
DEWETRON TRION driver | 7.0.0.2733</code></p>
<p><code>## Files<br />
### DEWE3 Frontend remote update<br />
frontend_swupdate_7.0.0.2733_146.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_7.0.0.2733_146.img.zip</code></p>
<p><code>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</code></p>
<p><code>## New Features and most important bugfixes:<br />
* Allow device network configuration even if ip settings do not match<br />
* Node default name is the serial number<br />
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected<br />
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal</code></p>
<p><code>## New Firmwares</code></p>
<p><code>HW Support TRION modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-1820-MULTI-4-D | FW: x0043<br />
TRION3-1820-MULTI-8-L0B | FW: x0043<br />
TRION3-1850-MULTI-4-D | FW: x0043<br />
TRION3-1850-MULTI-8-L0B | FW: x0043<br />
TRION3-1801-MULTI-8-L0B | FW: x0043<br />
TRION-1820-MULTI-4-D | FW: x0043</code></p>
advancedOnly(false)
internalOnly(false)
nameFRONTEND Firmware R7.0.0: Create new USB update stick
description<p><code>## 2024-02-01 Release Notice DEWETRON Frontend Firmware R7.0.0</code></p>
<p><code>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</code></p>
<p><code>Revision: c8730c64bd0f421a4b0a87b70977e5b072fa9e1e</code></p>
<p><code>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto kirkstone-4.0.11<br />
DEWETRON TRIONet Server | 7.0.0.2733<br />
DEWETRON TRION API | 7.0.0.2733<br />
DEWETRON TRION driver | 7.0.0.2733</code></p>
<p><code>## Files<br />
### DEWE3 Frontend remote update<br />
frontend_swupdate_7.0.0.2733_146.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_7.0.0.2733_146.img.zip</code></p>
<p><code>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</code></p>
<p><code>## New Features and most important bugfixes:<br />
* Allow device network configuration even if ip settings do not match<br />
* Node default name is the serial number<br />
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected<br />
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal</code></p>
<p><code>## New Firmwares</code></p>
<p><code>HW Support TRION modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-1820-MULTI-4-D | FW: x0043<br />
TRION3-1820-MULTI-8-L0B | FW: x0043<br />
TRION3-1850-MULTI-4-D | FW: x0043<br />
TRION3-1850-MULTI-8-L0B | FW: x0043<br />
TRION3-1801-MULTI-8-L0B | FW: x0043<br />
TRION-1820-MULTI-4-D | FW: x0043</code></p>
advancedOnly(false)
internalOnly(false)
nameFRONTEND Firmware R7.0.0: Update files for existing USB stick
description<p><code>## 2024-02-01 Release Notice DEWETRON Frontend Firmware R7.0.0</code></p>
<p><code>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</code></p>
<p><code>Revision: c8730c64bd0f421a4b0a87b70977e5b072fa9e1e</code></p>
<p><code>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto kirkstone-4.0.11<br />
DEWETRON TRIONet Server | 7.0.0.2733<br />
DEWETRON TRION API | 7.0.0.2733<br />
DEWETRON TRION driver | 7.0.0.2733</code></p>
<p><code>## Files<br />
### DEWE3 Frontend remote update<br />
frontend_swupdate_7.0.0.2733_146.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_7.0.0.2733_146.img.zip</code></p>
<p><code>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</code></p>
<p><code>## New Features and most important bugfixes:<br />
* Allow device network configuration even if ip settings do not match<br />
* Node default name is the serial number<br />
* Fix: ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected<br />
* Fix: ID002 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal</code></p>
<p><code>## New Firmwares</code></p>
<p><code>HW Support TRION modules | Firmware<br />
--------------------------------|-----------<br />
TRION3-1820-MULTI-4-D | FW: x0043<br />
TRION3-1820-MULTI-8-L0B | FW: x0043<br />
TRION3-1850-MULTI-4-D | FW: x0043<br />
TRION3-1850-MULTI-8-L0B | FW: x0043<br />
TRION3-1801-MULTI-8-L0B | FW: x0043<br />
TRION-1820-MULTI-4-D | FW: x0043</code></p>
description<p><code>## 2023-04-06 Release Notice DEWETRON Frontend Firmware R6.5.0</code></p>
<p><code>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</code></p>
<p><code>Revision: 9e970878a0cc93cb8feb59887baf979e3bb7a7a9</code></p>
<p><code>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto warrior-21.0.3<br />
DEWETRON TRIONet Server | 6.5.0.65371<br />
DEWETRON TRION API | 6.5.0.65371<br />
DEWETRON TRION driver | 6.5.0.65371</code></p>
<p><br />
<code>## Files<br />
### DEWE3 Frontend remote update<br />
update-image-frontend-6.5.0.65371.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_6.5.0.65371.zip</code></p>
<p><code>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</code></p>
<p><code>## New Features and most important bugfixes:<br />
* Fixed an issue when TRIONet device wre not shown after changing IP settings</code></p>
<p><code>## New Features and most important bugfixes:<br />
* TRION3-18XX-MULTI, TRION-18XX-MULTI higher sensor excitation power<br />
- up to 1W for 24V setting<br />
* TRION3-1802-dLV: Full support added<br />
* TRION3-1600-dLV: Full support added</code></p>
<p><code>## Known Limitations<br />
* Only one ethernet port usable.</code></p>
<p> </p>
advancedOnly(false)
internalOnly(false)
nameFRONTEND Firmware R6.5.0: Create new USB update stick
description<p><code>## 2023-04-06 Release Notice DEWETRON Frontend Firmware R6.5.0</code></p>
<p><code>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</code></p>
<p><code>Revision: 9e970878a0cc93cb8feb59887baf979e3bb7a7a9</code></p>
<p><code>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto warrior-21.0.3<br />
DEWETRON TRIONet Server | 6.5.0.65371<br />
DEWETRON TRION API | 6.5.0.65371<br />
DEWETRON TRION driver | 6.5.0.65371</code></p>
<p><br />
<code>## Files<br />
### DEWE3 Frontend remote update<br />
update-image-frontend-6.5.0.65371.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_6.5.0.65371.zip</code></p>
<p><code>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</code></p>
<p><code>## New Features and most important bugfixes:<br />
* Fixed an issue when TRIONet device wre not shown after changing IP settings</code></p>
<p><code>## New Features and most important bugfixes:<br />
* TRION3-18XX-MULTI, TRION-18XX-MULTI higher sensor excitation power<br />
- up to 1W for 24V setting<br />
* TRION3-1802-dLV: Full support added<br />
* TRION3-1600-dLV: Full support added</code></p>
<p><code>## Known Limitations<br />
* Only one ethernet port usable.</code></p>
<p> </p>
advancedOnly(false)
internalOnly(false)
nameFRONTEND Firmware R6.5.0: Update files for existing USB stick
description<p><code>## 2023-10-23 Release Notice DEWETRON Frontend Firmware R6.7.1</code></p>
<p><code>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</code></p>
<p><code>Revision: 1ee33ea7162d4418af9de534a019b5426b815472</code></p>
<p><code>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto kirkstone-4.0.11<br />
DEWETRON TRIONet Server | 6.7.1.1582<br />
DEWETRON TRION API | 6.7.1.1582<br />
DEWETRON TRION driver | 6.7.1.1582</code></p>
<p><code>## Files<br />
### DEWE3 Frontend remote update<br />
frontend_swupdate_6.7.1.1582_109.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_6.7.1.1582_109.img.zip</code></p>
<p><code>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</code></p>
<p><code>## New Features and most important bugfixes:<br />
* IP Config: Set factory default IP address to DHCP with autoip (LL) fallback<br />
* TRION driver fix for last 32bit addressable page (Debian Linux OS)</code></p>
<p><code>## Known Limitations<br />
* Only one ethernet port usable.</code></p>
<p> </p>
advancedOnly(false)
internalOnly(false)
nameFRONTEND Firmware R6.7.1: Update files for existing USB stick
description<p><tt>## 2023-12-04 Release Notice DEWETRON Frontend Firmware R6.7.2</tt></p>
<p><tt>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</tt></p>
<p><tt>Revision: 6e29cade2bda4c122e6674a6263aeb6b6bb16c2c</tt></p>
<p><tt>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto kirkstone-4.0.11<br />
DEWETRON TRIONet Server | 6.7.2.2175<br />
DEWETRON TRION API | 6.7.2.2175<br />
DEWETRON TRION driver | 6.7.2.2175</tt></p>
<p><tt>## Files<br />
### DEWE3 Frontend remote update<br />
frontend_swupdate_6.7.2.2175_113.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_6.7.2.2175_113.img.zip</tt></p>
<p><tt>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</tt></p>
<p><tt>## New Features and most important bugfixes<br />
* TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal<br />
* trion_cal: TRION-18XX-MULTI, allow AUTO and 0Hz for HP-Filter in XML<br />
* CHASSIS-CONTROLLER-V2: Fixed an issue with spikes when using CAN OUT (new fw)</tt></p>
<p><tt>## Known Limitations<br />
* ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected</tt></p>
advancedOnly(false)
internalOnly(false)
nameFRONTEND Firmware R6.7.2: Update files for existing USB stick
description<p><code>## 2023-04-06 Release Notice DEWETRON Frontend Firmware R6.5.0</code></p>
<p><code>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</code></p>
<p><code>Revision: 9e970878a0cc93cb8feb59887baf979e3bb7a7a9</code></p>
<p><code>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto warrior-21.0.3<br />
DEWETRON TRIONet Server | 6.5.0.65371<br />
DEWETRON TRION API | 6.5.0.65371<br />
DEWETRON TRION driver | 6.5.0.65371</code></p>
<p><br />
<code>## Files<br />
### DEWE3 Frontend remote update<br />
update-image-frontend-6.5.0.65371.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_6.5.0.65371.zip</code></p>
<p><code>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</code></p>
<p><code>## New Features and most important bugfixes:<br />
* Fixed an issue when TRIONet device wre not shown after changing IP settings</code></p>
<p><code>## New Features and most important bugfixes:<br />
* TRION3-18XX-MULTI, TRION-18XX-MULTI higher sensor excitation power<br />
- up to 1W for 24V setting<br />
* TRION3-1802-dLV: Full support added<br />
* TRION3-1600-dLV: Full support added</code></p>
<p><code>## Known Limitations<br />
* Only one ethernet port usable.</code></p>
<p> </p>
description<p><code>## 2023-10-23 Release Notice DEWETRON Frontend Firmware R6.7.1</code></p>
<p><code>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</code></p>
<p><code>Revision: 1ee33ea7162d4418af9de534a019b5426b815472</code></p>
<p><code>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto kirkstone-4.0.11<br />
DEWETRON TRIONet Server | 6.7.1.1582<br />
DEWETRON TRION API | 6.7.1.1582<br />
DEWETRON TRION driver | 6.7.1.1582</code></p>
<p><code>## Files<br />
### DEWE3 Frontend remote update<br />
frontend_swupdate_6.7.1.1582_109.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_6.7.1.1582_109.img.zip</code></p>
<p><code>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</code></p>
<p><code>## New Features and most important bugfixes:<br />
* IP Config: Set factory default IP address to DHCP with autoip (LL) fallback<br />
* TRION driver fix for last 32bit addressable page (Debian Linux OS)</code></p>
<p><code>## Known Limitations<br />
* Only one ethernet port usable.</code></p>
<p> </p>
description<p><tt>## 2023-12-04 Release Notice DEWETRON Frontend Firmware R6.7.2</tt></p>
<p><tt>## Description:<br />
Software Release for selected DEWETRON DEWE3 enclosures allowing them<br />
to operate like TRIONet devices including multiple frontends and TRION-SYNC.<br />
Released for DEWE3-RMx and DEWE3-Mx.</tt></p>
<p><tt>Revision: 6e29cade2bda4c122e6674a6263aeb6b6bb16c2c</tt></p>
<p><tt>Components | Version<br />
--------------------------------|--------------------------<br />
OS | Yocto kirkstone-4.0.11<br />
DEWETRON TRIONet Server | 6.7.2.2175<br />
DEWETRON TRION API | 6.7.2.2175<br />
DEWETRON TRION driver | 6.7.2.2175</tt></p>
<p><tt>## Files<br />
### DEWE3 Frontend remote update<br />
frontend_swupdate_6.7.2.2175_113.swu<br />
### DEWE3 Frontend USB stick image<br />
frontend_update_stick_image_6.7.2.2175_113.img.zip</tt></p>
<p><tt>## Requirements<br />
* All FRONTEND devices used with OXYGEN should be updated to the image included in this release</tt></p>
<p><tt>## New Features and most important bugfixes<br />
* TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) is distorting the input signal<br />
* trion_cal: TRION-18XX-MULTI, allow AUTO and 0Hz for HP-Filter in XML<br />
* CHASSIS-CONTROLLER-V2: Fixed an issue with spikes when using CAN OUT (new fw)</tt></p>
<p><tt>## Known Limitations<br />
* ID001 - TRION(3)-18xx-MULTI Highpass Filters (0.16Hz - 100Hz) show 64% overshoot and higher cutoff frequencies than expected</tt></p>
description<p><tt>## 2025-03-05 Release Notice DEWETRON TRION API R7.4.2<br />
Revision: 38d9842531ceafe409e38f55812f2da2aa53be1a<br />
Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 7.4.2.7598<br />
DEWETRON TRION API | 7.4.2.7598<br />
DEWETRON TRION driver | 7.4.2.7598<br />
DEWETRON DEWE2 driver | 7.4.2.7598<br />
## Files<br />
DEWETRON-TRION-Applications-7.4.2.7598.exe<br />
## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R7.4.2 or higher<br />
* Windows 10 64-Bit or better<br />
## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade<br />
## Fixes and Changes<br />
* TRIONet API returned an invalid number of samples when using i64 getter function<br />
* Removed prototype boards listed in DEWETRON Explorer</tt><br />
<br />
</p>
description<p><tt>## 2025-03-05 Release Notice DEWETRON TRION API R7.4.2<br />
Revision: 38d9842531ceafe409e38f55812f2da2aa53be1a<br />
Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 7.4.2.7598<br />
DEWETRON TRION API | 7.4.2.7598<br />
DEWETRON TRION driver | 7.4.2.7598<br />
DEWETRON DEWE2 driver | 7.4.2.7598<br />
## Files<br />
DEWETRON-TRION-Applications-7.4.2.7598.exe<br />
## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R7.4.2 or higher<br />
* Windows 10 64-Bit or better<br />
## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade<br />
## Fixes and Changes<br />
* TRIONet API returned an invalid number of samples when using i64 getter function<br />
* Removed prototype boards listed in DEWETRON Explorer</tt><br />
<br />
</p>
description<p><tt>## 2024-08-27 Release Notice DEWETRON TRION API R7.2.1</tt></p>
<p><tt>Revision: 876a648bcaebd47fe225e89ab132256fce382190</tt></p>
<p><tt>Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 7.2.1.5243<br />
DEWETRON TRION API | 7.2.1.5243<br />
DEWETRON TRION driver | 7.2.1.5243<br />
DEWETRON DEWE2 driver | 7.2.1.5243</tt></p>
<p><tt>## Files<br />
DEWETRON-TRION-Applications-7.2.1.5243.exe</tt></p>
<p><tt>## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R7.2.0 or higher<br />
* Windows 10 64-Bit or better</tt></p>
<p><tt>## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade</tt></p>
<p><tt>## Fixes<br />
* NEX[DAQ]-1000 simulation sample rate divider support fixed.</tt></p>
description<p><tt>## 2024-08-27 Release Notice DEWETRON TRION API R7.2.1</tt></p>
<p><tt>Revision: 876a648bcaebd47fe225e89ab132256fce382190</tt></p>
<p><tt>Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 7.2.1.5243<br />
DEWETRON TRION API | 7.2.1.5243<br />
DEWETRON TRION driver | 7.2.1.5243<br />
DEWETRON DEWE2 driver | 7.2.1.5243</tt></p>
<p><tt>## Files<br />
DEWETRON-TRION-Applications-7.2.1.5243.exe</tt></p>
<p><tt>## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R7.2.0 or higher<br />
* Windows 10 64-Bit or better</tt></p>
<p><tt>## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade</tt></p>
<p><tt>## Fixes<br />
* NEX[DAQ]-1000 simulation sample rate divider support fixed.</tt></p>
description<p><tt>## 2024-11-20 Release Notice DEWETRON TRION API R7.3.2<br />
Revision: f6f8bf5b1b38b78b8d8a67761130412adeb7e977<br />
Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 7.3.2.6198<br />
DEWETRON TRION API | 7.3.2.6198<br />
DEWETRON TRION driver | 7.3.2.6198<br />
DEWETRON DEWE2 driver | 7.3.2.6198<br />
## Files<br />
DEWETRON-TRION-Applications-7.3.2.6198.exe<br />
## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R7.3.2 or higher<br />
* Windows 10 64-Bit or better<br />
## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade<br />
## Fixes<br />
* Fix for semaphore handling of date and time changes.</tt></p>
description<p><tt>## 2024-11-20 Release Notice DEWETRON TRION API R7.3.2<br />
Revision: f6f8bf5b1b38b78b8d8a67761130412adeb7e977<br />
Components | Version<br />
--------------------------------|--------------------------<br />
DEWETRON Explorer | 7.3.2.6198<br />
DEWETRON TRION API | 7.3.2.6198<br />
DEWETRON TRION driver | 7.3.2.6198<br />
DEWETRON DEWE2 driver | 7.3.2.6198<br />
## Files<br />
DEWETRON-TRION-Applications-7.3.2.6198.exe<br />
## Requirements<br />
* Update all TRION modules to the latest firmware included in this release<br />
* Use OXYGEN R7.3.2 or higher<br />
* Windows 10 64-Bit or better<br />
## Installation procedure<br />
* Install TRION applications<br />
* Reboot system (if requested by the installer)<br />
* Start DEWETRON Explorer and update each TRION board firmware to latest version (right-click on enclosure name)<br />
* Power-cycle TRION boards (Power down system, then restart)<br />
* Start DEWETRON Explorer and check for a successful firmware upgrade<br />
## Fixes<br />
* Fix for semaphore handling of date and time changes.</tt><br />
</p>